An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography

被引:120
作者
Clarke, AP [1 ]
Jandik, P [1 ]
Rocklin, RD [1 ]
Liu, Y [1 ]
Avdalovic, N [1 ]
机构
[1] Dionex Corp, Sunnyvale, CA 94088 USA
关键词
D O I
10.1021/ac9811524
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a new detection method that uses a six-potential waveform to detect all amino acids without derivatization. The detection limits are less than 1 pmol for most of the analytes. The anion-exchange separation uses a ternary gradient with water, 0.25 M sodium hydroxide, and 1.0 M sodium acetate. We present results of waveform optimization experiments designed to minimize gradient artifacts and to achieve optimum conditions for the quantitative analysis of common amino acids. Analytical results for protein hydrolysates are discussed and compared with those obtained by cation exchange followed by ninhydrin derivatization and spectrophotometric detection.
引用
收藏
页码:2774 / 2781
页数:8
相关论文
共 14 条
[1]   SYNTHESIS OF A FLUORESCENT DERIVATIZING REAGENT, 6-AMINOQUINOLYL-N-HYDROXYSUCCINIMIDYL CARBAMATE, AND ITS APPLICATION FOR THE ANALYSIS OF HYDROLYSATE AMINO-ACIDS VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COHEN, SA ;
MICHAUD, DP .
ANALYTICAL BIOCHEMISTRY, 1993, 211 (02) :279-287
[2]   PULSED ELECTROCHEMICAL DETECTION AT THE RING OF A RING-DISK ELECTRODE APPLIED TO A STUDY OF AMINE ADSORPTION AT GOLD ELECTRODES [J].
DOBBERPUHL, DA ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1995, 67 (07) :1254-1258
[3]  
JOHNSON DC, 1994, CARBOHYDRATE ANAL HI, pCH10
[4]   ANION-EXCHANGE SEPARATION OF CARBOHYDRATES WITH PULSED AMPEROMETRIC DETECTION USING A PH-SELECTIVE REFERENCE ELECTRODE [J].
LACOURSE, WR ;
MEAD, DA ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :220-224
[5]  
LaCourse WR, 1997, PULSED ELECTROCHEMIC
[6]   PULSED AMPEROMETRIC DETECTION OF AMINO-ACIDS SEPARATED BY ANION-EXCHANGE CHROMATOGRAPHY [J].
MARTENS, DA ;
FRANKENBERGER, WT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (03) :423-439
[7]   THE DIRECT ELECTROCHEMICAL DETECTION OF AMINO-ACIDS AT A PLATINUM-ELECTRODE IN AN ALKALINE CHROMATOGRAPHIC EFFLUENT [J].
POLTA, JA ;
JOHNSON, DC .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (10) :1727-1743
[8]   Improved long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform [J].
Rocklin, RD ;
Clarke, AP ;
Weitzhandler, M .
ANALYTICAL CHEMISTRY, 1998, 70 (08) :1496-1501
[9]  
SMITH AJ, 1997, PROTEIN SEQUENCING P, pCH15
[10]   AUTOMATIC RECORDING APPARATUS FOR USE IN THE CHROMATOGRAPHY OF AMINO ACIDS [J].
SPACKMAN, DH ;
STEIN, WH ;
MOORE, S .
ANALYTICAL CHEMISTRY, 1958, 30 (07) :1190-1206