Analysis of Hanford-related organics using matrix-assisted laser desorption ionization time-of-flight mass spectrometry

被引:3
作者
Campbell, JA [1 ]
Hess, WP [1 ]
Lohman, JR [1 ]
Goheen, SC [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
D O I
10.1023/A:1017954420787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Matrix-assisted laser desorption/ionization coupled with time-of-flight mass spectrometry (MALDI/TOF-MS) was used for the analysis of low-molecular phosphate compounds found in Hanford tank wastes. The mass spectra of these compounds indicate protonated peaks as well as sodium adducts. Analytical methods presently utilized for the analysis of the phosphate-related organics are both time consuming and labor intensive. A promising alternative is MALDI/TOFMS. The MALDI process produces both positive and negative ions directly and very little sample is required. In addition, there is limited sample preparation and minimal hazardous waste production.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 27 条
[1]  
ALLEN GK, 1976, ARHCD6108
[2]  
BABAD H, 1996, WHCSDWMTI756
[3]  
Bartlett MG, 1996, J MASS SPECTROM, V31, P275, DOI 10.1002/(SICI)1096-9888(199603)31:3<275::AID-JMS294>3.0.CO
[4]  
2-Q
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC, STABILITY INDICATING ASSAY FOR DISODIUM EDTA IN OPHTHALMIC PREPARATIONS [J].
BAUER, J ;
HEATHCOTE, D ;
KROGH, S .
JOURNAL OF CHROMATOGRAPHY, 1986, 369 (02) :422-425
[6]   ORGANIC-ANALYSIS AT THE HANFORD-NUCLEAR-SITE [J].
CAMPBELL, JA ;
STROMATT, RW ;
SMITH, MR ;
KOPPENAAL, DW ;
BEAN, RM ;
JONES, TE ;
STRACHAN, DM ;
BABAD, H .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :A1208-A1215
[7]  
CAMPBELL JA, 1994, PNL9062
[8]  
CAMPBELL JA, 1991, P 39 ASMS C MASS SPE, P1334
[9]  
CAMPBELL JA, 1992, P 40 ASMS C MASS SPE
[10]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF NITRILOTRIACETIC ACID, ETHYLENEDIAMINETETRAACETIC ACID, AND RELATED AMINOPOLYCARBOXYLIC ACIDS USING AN AMPEROMETRIC DETECTOR [J].
DAI, J ;
HELZ, GR .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :301-305