Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part I. Reversed-phase liquid chromatography

被引:48
作者
Jandera, Pavel [1 ]
Stankova, Magda [1 ]
Skerikova, Veronika [1 ]
Urban, Jiri [1 ]
机构
[1] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Pardubice 53210, Czech Republic
关键词
Organic-polymer momoliths; Column efficiency; Capillary HPLC; Pore size distribution; POROUS POLYMER MONOLITHS; LARGE SURFACE-AREA; SMALL MOLECULES; METHACRYLATE MONOLITHS; MACROPOROUS POLYMERS; STATIONARY PHASES; SIZE DISTRIBUTION; CARBON NANOTUBES; PORE FORMATION; PERFORMANCE;
D O I
10.1016/j.chroma.2012.12.003
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
We synthesized 8 polymethacrylate monolithic capillary columns using laurylmethacrylate functional monomer and various cross-linking monomers differing in the polarity and size. The efficiency of monolithic columns for low-molecular compounds significantly improved with increasing number of repeat non-polar methylene groups in the cross-linker molecules, correlating with greater proportion of small pores with size less than 50 nm. The best efficiency with HETP = 25 mu m for alkylbenzenes was achieved for columns prepared using hexamethylene dimethacrylate (HEDMA). Columns prepared with polar (poly)oxyethylene dimethacrylate cross-linkers show also improved efficiency with increasing chain length and generally better performance in comparison to the (poly)methylene dimethacrylate cross-linkers of comparable size, however with less apparent effects of the chain lengths on the pore distribution. The monolithic columns prepared with tetraoxyethylene dimethacrylate (TeEDMA) showed the best efficiency of all the columns tested, corresponding to HETP = 15 mu m (approx. 70,000 theoretical plates/m), show excellent column-to-column reproducibility with standard deviations of 2.5% in retention times, good permeability and low mass transfer resistance, so that is suitable for fast separation of low-molecular compounds in 2 min or less. By modification of the fused-silica capillary inner walls pretreatment procedure, very good long-term stability was achieved even in 0.5 mm i.d. capillary format. The TeEDMA column can be also used for size-exclusion chromatography of lower non-polar synthetic polymers, whereas it is less suitable for separations of proteins than the HEDMA column. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 59 条
[1]
Preparation of glycerol dimethacrylate-based polymer monolith with unusual porous properties achieved via viscoelastic phase separation induced by monodisperse ultra high molecular weight poly(styrene) as a porogen [J].
Aoki, Hiroshi ;
Kubo, Takuya ;
Ikegami, Tohru ;
Tanaka, Nobuo ;
Hosoya, Ken ;
Tokuda, Daisuke ;
Ishizuka, Norio .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1119 (1-2) :66-79
[2]
Recent developments and future possibilities for polymer monoliths in separation science [J].
Arrua, R. Dario ;
Causon, Tim J. ;
Hilder, Emily F. .
ANALYST, 2012, 137 (22) :5179-5189
[3]
Review of recent advances in the preparation of organic polymer monoliths for liquid chromatography of large molecules [J].
Arrua, R. Dario ;
Talebi, Mohammad ;
Causon, Tim J. ;
Hilder, Emily F. .
ANALYTICA CHIMICA ACTA, 2012, 738 :1-12
[4]
Study of bed homogenity of methacrylate-based monolithic columns for micro-HPLC and CEC [J].
Buszewski, B ;
Szumski, M .
CHROMATOGRAPHIA, 2004, 60 (Suppl 1) :S261-S267
[5]
Porous Polymer Monoliths Functionalized through Copolymerization of a C60 Fullerene-Containing Methacrylate Monomer for Highly Efficient Separations of Small Molecules [J].
Chambers, Stuart D. ;
Holcombe, Thomas W. ;
Svec, Frantisek ;
Frechet, Jean M. J. .
ANALYTICAL CHEMISTRY, 2011, 83 (24) :9478-9484
[6]
Incorporation of carbon nanotubes in porous polymer monolithic capillary columns to enhance the chromatographic separation of small molecules [J].
Chambers, Stuart D. ;
Svec, Frantisek ;
Frechet, Jean M. J. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (18) :2546-2552
[7]
Methacrylate monolithic columns of 320 μm ID for capillary liquid chromatography [J].
Coufal, P ;
Cihák, M ;
Suchánková, J ;
Tesarová, E ;
Bosáková, Z ;
Stulík, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :99-106
[8]
Davankov V. A., 1971, US Pat, Patent No. [3729457, 3,729,457]
[9]
Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography [J].
Eeltink, S ;
Herrero-Martinez, JM ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7342-7347
[10]
Optimization of the porous structure and polarity of polymethacrylate-based monolithic capillary columns for the LC-MS separation of enzymatic digests [J].
Eeltink, Sebastiaan ;
Geiser, Laurent ;
Svec, Frantisek ;
Frechet, Jean M. J. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (17) :2814-2820