Risk factors for failure after treatment of a periprosthetic fracture of the femur

被引:230
作者
Lindahl, H [1 ]
Malchau, H [1 ]
Odén, A [1 ]
Garellick, G [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Univ Hosp, Dept Orthopaed, SE-41345 Gothenburg, Sweden
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2006年 / 88B卷 / 01期
关键词
D O I
10.1302/0301-620X.88B1.17029
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic fracture of the femur is an uncommon complication after total hip replacement, but appears to be increasing. We undertook a nationwide observational study to determine the risk factors for failure after treatment of these fractures, examining patient- and implant-related factors, the classification of the fractures and the outcome. Between 1979 and 2000, 1049 periprosthetic fractures of the femur were reported to the Swedish National Hip Arthroplasty Register. Of these, 245 had a further operation after failure of their initial management. Data were collected from the Register and hospital records. The material was analysed by the use of Poisson regression models. It was found that the risk of failure of treatment was reduced for Vancouver type B2 injuries (p = 0.0053) if revision of the implant was undertaken (p = 0.0033) or revision and open reduction and internal fixation (p = 0.0039) were performed. Fractures classified as Vancouver type B1 had a significantly higher risk of failure (p = 0.0001). The strongest negative factor was the use of a single plate for fixation (p = 0.001). The most common reasons for failure in this group were loosening of the femoral prosthesis, nonunion and refracture. It is probable that many fractures classified as Vancouver type B1 (n = 304), were in reality type B2 fractures with a loose stem which were not recognised. Plate fixation was inadequate in these cases. The difficulty in separating type B1 from type B2 fractures suggests that the prosthesis should be considered as loose until proven otherwise.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 25 条
[1]
The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty [J].
Ahuja, S ;
Chatterji, S .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01) :47-50
[2]
Periprosthetic fractures with extensive bone loss treated with onlay strut allografts [J].
Barden, B ;
von Knoch, M ;
Fitzek, JG ;
Löer, F .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (03) :164-167
[3]
Epidemiology - Hip and knee [J].
Berry, DJ .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :183-+
[4]
Management of periprosthetic fractures - The hip [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :11-13
[5]
BOOTH RE, 1994, ORTHOPEDICS, V17, P845
[6]
The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :249-+
[7]
Classification of the hip [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :215-+
[8]
The reliability and validity of the Vancouver classification of femoral fractures after hip replacement [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :59-62
[9]
COURPIED JP, 1987, INT ORTHOP, V11, P109
[10]
Day NE., 1987, STATISTICAL METHODS, VII, P131