Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults

被引:23
作者
Erdem, Abdullah [1 ]
Saritas, Turkay [1 ]
Zeybek, Cenap [2 ]
Yucel, Ilker Kemal [1 ]
Erol, Nurdan [1 ]
Demir, Halil [1 ]
Odemis, Ender [1 ]
Yalcin, Yalim [2 ]
Celebi, Ahmet
机构
[1] Dr Siyami Ersek Thorac & Cardiovasc Surg Ctr, Dept Pediat Cardiol, TR-34672 Istanbul, Turkey
[2] Medicana Int Hosp, Dept Pediat Cardiol, Istanbul, Turkey
关键词
Atrial septal defect; Echocardiography; Occluders; Transcatheter closure; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; PERCUTANEOUS CLOSURE; OCCLUSION; DEVICE; OCCLUDER; SAFETY;
D O I
10.1007/s10554-011-9933-z
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The purpose of this study was to evaluate the safety and efficacy of transcatheter Atrial septal defect (ASD) closure guided by transthoracic echocardiography (TTE). Since 2004, ASD closure was performed successfully in total 337 patients. Transthoracic echocardiography guidance was used in 206 patients (61.1%) (group 1). Closure was guided by transesophageal echocardiography under general anesthesia in patients with poor transthoracic acoustic windows, defects with aneurysmatic septum and/or multiple defects in 131 patients (38.9%) (group 2). The median age (9 vs. 16 years, P < 0.001), mean defect diameter (14.9 +/- A 4 vs. 17.2 +/- A 5 mm, P < 0.001), ratio of complex atrial septal defect (14 vs. 34%, P = 0.01), the median balloon stretch dimensions (21 vs. 18.7 mm, P = 0.003) and the median device diameters (22 vs. 19 mm, P < 0.001) were significantly greater in group 2 compared to group 1. Both the median procedure time and the median fluoroscopy time was significantly shorter in group 1 (60 vs. 75; and 13 vs. 16.5 min; P < 0.0001 and P < 0.0001, respectively). The incidence of residual shunt did not differ significantly in two groups during follow up. Transthoracic echocardiography guidance during transcatheter ASD closure is safe and effective in children and in many adults. Even complex ASDs could be closed with TTE in patients with good acoustic windows. Performing the procedure under TTE guidance significantly reduces procedure time and also provides increased patient's comfort.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 26 条
[1]
Agricola Eustachio, 2004, Expert Rev Cardiovasc Ther, V2, P61, DOI 10.1586/14779072.2.1.61
[2]
Awad Sawsan M, 2009, Curr Cardiol Rep, V11, P210
[3]
Bialkowski J, 2010, CARDIOL J, V17, P607
[4]
CardioSEAL/STARflex versus Amplatzer devices for percutaneous closure of small to moderate (up to 18 mm) atrial septal defects [J].
Butera, G ;
Carminati, M ;
Chessa, M ;
Delogu, A ;
Drago, M ;
Piazza, L ;
Giamberti, A ;
Frigiola, A .
AMERICAN HEART JOURNAL, 2004, 148 (03) :507-510
[5]
Early and late complications associated with transcatheter occlusion of secundum atrial septal defect [J].
Chessa, M ;
Carminati, M ;
Butera, G ;
Bini, RM ;
Drago, M ;
Rosti, L ;
Giamberti, A ;
Pomè, G ;
Bossone, E ;
Frigiola, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) :1061-1065
[6]
Contrafouris Constantinos A, 2006, Hellenic J Cardiol, V47, P245
[7]
de Lezo JS, 2000, CATHETER CARDIO INTE, V51, P33
[8]
Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults - Results of a multicenter nonrandomized trial [J].
Du, ZD ;
Hijazi, ZM ;
Kleinman, CS ;
Silverman, NH ;
Larnitz, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (11) :1836-1844
[9]
Elzenga NJ, 2000, CARDIOL YOUNG, V10, P474
[10]
TRANSESOPHAGEAL ECHOCARDIOGRAPHIC GUIDANCE OF TRANSCATHETER CLOSURE OF ATRIAL SEPTAL-DEFECT [J].
HELLENBRAND, WE ;
FAHEY, JT ;
MCGOWAN, FX ;
WELTIN, GG ;
KLEINMAN, CS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :207-213