Thermal analysis of dental resins cured with blue light-emitting diodes (LEDs)

被引:41
作者
Nomura, Y
Teshima, W
Tanaka, N
Yoshida, Y
Nahara, Y
Okazaki, M
机构
[1] Hiroshima Univ, Fac Dent, Dept Biomat Sci, Minami Ku, Hiroshima 7348553, Japan
[2] Hiroshima Univ, Fac Dent, Special Dent Clin Sect, Hiroshima, Japan
[3] Hiroshima Univ, Fac Dent, Dept Operat Dent, Hiroshima, Japan
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 02期
关键词
dental resin; light-emitting diodes (LEDs); thermal analysis; activation energy; Knoop hardness;
D O I
10.1002/jbm.10126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thermal analysis was used to measure the characteristics of dental resins cured with the use of a new light-activation unit equipped with high illuminant blue light-emitting diodes (LEDs). The characteristics were compared with those of resins cured with the use of two conventional halogen lamp units. The prepared base monomer consisted of a mixture of Bis-GMA and TEGDMA (60:40 by weight), with 0.5 wt% CQ/DMPT or CQ/DMAEMA. The two experimental visible-fight-cured resins were polymerized for 40 s. Differential scanning calorimetry (DSC) was used to examine the thermal characteristics of the cured resins. The activation energy for the decomposition of the dental resin was calculated from the peaks of the endothermic curves obtained when the specimens were heated at three different rates (5, 10, and 15 degreesC/min) during DSC. The activation energies calculated for the LED-cured specimens were more than 220 kJ/mol; specimens cured with the use of the halogen units had activation energies of less than 192 kJ/mol. The Knoop hardness number (KHN) of the same specimens was measured, and was higher with the blue LED units than with halogen lamp units. Therefore, dental resins cured using blue LEDs have a higher degree of polymerization and more stable three-dimensional structures than those cured with halogen lamps. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 23 条
[1]   EXTENT OF POLYMERIZATION OF DENTAL RESINS BY DIFFERENTIAL SCANNING CALORIMETRY [J].
ANTONUCCI, JM ;
TOTH, EE .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :121-125
[2]   SOME FACTORS INFLUENCING THE DEPTH OF CURE OF VISIBLE LIGHT-ACTIVATED COMPOSITE RESINS [J].
ATMADJA, G ;
BRYANT, RW .
AUSTRALIAN DENTAL JOURNAL, 1990, 35 (03) :213-218
[3]   EVALUATING INTENSITY OUTPUT OF CURING LIGHTS IN PRIVATE DENTAL OFFICES [J].
BARGHI, N ;
BERRY, T ;
HATTON, C .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (07) :992-996
[4]   SPECTRAL DISTRIBUTIONS OF DENTAL PHOTO-POLYMERIZATION SOURCES [J].
COOK, WD .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (12) :1436-1438
[5]  
CRAIG RG, 1981, DENT CLIN N AM, V25, P219
[6]   DYNAMIC MECHANICAL-PROPERTIES OF AN INLAY COMPOSITE [J].
DIONYSOPOULOS, P ;
WATTS, DC .
JOURNAL OF DENTISTRY, 1989, 17 (03) :140-144
[7]  
Ferracane J L, 1985, Dent Mater, V1, P11, DOI 10.1016/S0109-5641(85)80058-0
[8]   RATE OF ELUTION OF LEACHABLE COMPONENTS FROM COMPOSITE [J].
FERRACANE, JL ;
CONDON, JR .
DENTAL MATERIALS, 1990, 6 (04) :282-287
[9]  
FUJIBAYASHI K, 1996, J JAP DENT PRES ACAD, V39, P180
[10]  
Imazato S, 1995, Dent Mater J, V14, P23