Lipophilicity data for some preservatives estimated by reversed-phase liquid chromatography and different computation methods

被引:57
作者
Casoni, Dorina [1 ]
Kot-Wasik, Agata [2 ]
Namiesnik, Jacek [2 ]
Sarbu, Costel [1 ]
机构
[1] Univ Babes Bolyai, Fac Chem & Chem Engn, RO-400028 Cluj Napoca, Cluj, Romania
[2] Gdansk Univ Technol, Fac Chem, PL-80952 Gdansk, Poland
关键词
Preservatives; Reversed-phase HPLC; Lipophilicity indices; Computed log P; PCA; RETENTION BEHAVIOR; PARTITION-COEFFICIENTS; PUBLISHED LITERATURE; GRADIENT ELUTION; SYSTEMS; DRUGS; PREDICTION; INTERCEPT; MEMBRANE; PARABEN;
D O I
10.1016/j.chroma.2009.01.029
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The chromatographic behavior of some preservatives was performed by reversed-phase high-performance liquid chromatography on C18 (LiChroCART, Purosphere RP-18e), C8 (Zorbax. Eclipse XDB-C8), CN100 (Saulentechnik, Lichrosphere) and NH2 (Supelcosil LC-NH2) columns. The lipophilicity estimated for the first time on the first three columns are comparable and very well correlated. The mobile phase was a mixture of methanol-water (0.1% formic acid) in different volume proportions from 40% to 60% (v/v) for RP-C18, RP-C8 and RP-CN100 column (exception for parabens on RP-C8 column-the methanol concentrations being from 55% to 65%) and from 30% to 50% (v/v) for RP-NH2. Highly significant correlations were obtained between different experimental indices of lipophilicity (log k(w), S, phi(0), mean of k and log k, and scores of k and log k corresponding to the first principal component) and Computed log P values, and C8 Column seems to be more suited for estimating the lipophilicity of the investigated compounds. These direct correlations offer a very good opportunity to derive powerful predictive models via Collander-type equations. The reliability of scores values as lipophilic indices is shown by their high correlation with the log K., obtained using classical "shake-flask" technique. log k(w) and also some of the computed log P values. In addition, the results obtained applying PCA to the retention data may be used in interpreting the molecular mechanism of interactions between eluents and stationary phases with different polarity and to explain the chromatographic behavior of compounds. Finally, the "congeneric lipophilicity chart" described by the scores corresponding to the first principal component has the effect of separating compounds from each other more effectively from congeneric ((dis)similarity) point of view. The parabens and tert-butylhydroquinone appeared to be the most lipophilic preservatives. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2456 / 2465
页数:10
相关论文
共 34 条
[1]
[Anonymous], 1997, EUR J MED CHEM
[2]
MEASUREMENT OF LIPOPHILICITY INDEXES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - COMPARISON OF 2 STATIONARY PHASES AND VARIOUS ELUENTS [J].
BECHALANY, A ;
TSANTILIKAKOULIDOU, A ;
ELTAYAR, N ;
TESTA, B .
JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2) :221-229
[3]
RELATIONSHIP BETWEEN PI AND RM VALUES OF SULFONAMIDES [J].
BIAGI, GL ;
BARBARO, AM ;
GUERRA, MC ;
FORTI, GC ;
FRACASSO, ME .
JOURNAL OF MEDICINAL CHEMISTRY, 1974, 17 (01) :28-33
[4]
DETERMINATION OF THE ALKYL ESTERS OF P-HYDROXYBENZOIC ACID IN MAYONNAISE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE LABELING [J].
BURINI, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (02) :213-219
[5]
DETERMINATION OF SORBIC ACID IN MARGARINE AND BUTTER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BURINI, G ;
DAMIANI, P .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01) :69-80
[6]
PREDICTION OF RETENTION OF HYDROXYL AROMATICS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY WITH SLOPE INTERCEPT RELATIONSHIPS [J].
COOPER, HA ;
HURTUBISE, RJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 360 (02) :313-325
[7]
HYDROPHOBICITY ESTIMATIONS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY - IMPLICATIONS FOR BIOLOGICAL PARTITIONING PROCESSES [J].
DORSEY, JG ;
KHALEDI, MG .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :485-499
[8]
Current state of the art in HPLC methodology for lipophilicity assessment of basic drugs. A review [J].
Giaginis, Costas ;
Tsantili-Kakoulidou, Anna .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (01) :79-96
[9]
Intra-laboratory testing of method accuracy from recovery assays [J].
González, AG ;
Herrador, MA ;
Asuero, AG .
TALANTA, 1999, 48 (03) :729-736
[10]
Hansch C., 1995, Exploring QSAR