C60 Secondary Ion Mass Spectrometry with a Hybrid-Quadrupole Orthogonal Time-of-Flight Mass Spectrometer

被引:93
作者
Carado, Anthony [1 ]
Passarelli, M. K. [1 ]
Kozole, Joseph [1 ]
Wingate, J. E. [2 ]
Winograd, Nicholas [1 ]
Loboda, A. V. [2 ]
机构
[1] Penn State Univ, Dept Chem, University Pk, PA 16802 USA
[2] Appl Biosyst MDS Analyt Technol, Concord, ON, Canada
基金
美国国家科学基金会;
关键词
D O I
10.1021/ac801712s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hybrid quadrupole orthogonal time-of-flight mass spectrometer optimized for matrix-assisted laser desorption ionization (MALDI) and electrospray ionization has been equipped with a C-60 cluster ion source. This configuration is shown to exhibit a number of characteristics that improve the performance of traditional time-of-flight secondary ion mass spectrometry (TOF-SIMS) experiments for the analysis of complex organic materials and, potentially, for chemical imaging. Specifically, the primary ion beam is operated as a continuous rather than a pulsed beam, resulting in up to 4 orders of magnitude greater ion fluence on the target. The secondary ions are extracted at very low voltage into 8 mTorr of N-2 gas introduced for collisional focusing and cooling purposes. This extraction configuration is shown to yield secondary ions that rapidly lose memory of the mechanism of their birth, yielding tandem mass spectra that are identical for SIMS and MALDI. With implementation of ion trapping, the extraction efficiency is shown to be equivalent to that found in traditional TOF-SIMS machines. Examples are given, for a variety of substrates that illustrate mass resolution of 12 000 - 15 600 with a mass range for inorganic compounds to m/z 40 000. Preliminary chemical mapping experiments show that with added sensitivity, imaging in the MS/MS mode of operation is straightforward. In general, the combination of MALDI and SIMS is shown to add capabilities to each technique, providing a robust platform for TOF-SIMS experiments that already exists in a large number of laboratories.
引用
收藏
页码:7921 / 7929
页数:9
相关论文
共 43 条
[1]  
ADAM SA, 1992, METHOD ENZYMOL, V219, P97
[2]   NUCLEAR-PROTEIN IMPORT IN PERMEABILIZED MAMMALIAN-CELLS REQUIRES SOLUBLE CYTOPLASMIC FACTORS [J].
ADAM, SA ;
MARR, RS ;
GERACE, L .
JOURNAL OF CELL BIOLOGY, 1990, 111 (03) :807-816
[3]   SURFACE-ANALYSIS BY SECONDARY-ION MASS-SPECTROMETRY (SIMS) [J].
BENNINGHOVEN, A .
SURFACE SCIENCE, 1994, 299 (1-3) :246-260
[4]   Artifacts of MALDI sample preparation investigated by high-resolution scanning microprobe matrix-assisted laser desorption/ionization (SMALDI) imaging mass spectrometry [J].
Bouschen, Werner ;
Spengler, Bernhard .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 266 (1-3) :129-137
[5]  
Braun RM, 1998, RAPID COMMUN MASS SP, V12, P1246, DOI 10.1002/(SICI)1097-0231(19980930)12:18<1246::AID-RCM316>3.0.CO
[6]  
2-C
[7]   EFFECT OF CLUSTER SURFACE ENERGIES ON SECONDARY-ION-INTENSITY DISTRIBUTIONS FROM IONIC-CRYSTALS [J].
CAMPANA, JE ;
BARLAK, TM ;
COLTON, RJ ;
DECORPO, JJ ;
WYATT, JR ;
DUNLAP, BI .
PHYSICAL REVIEW LETTERS, 1981, 47 (15) :1046-1049
[8]  
CARADO A, APPL SURF A IN PRESS
[9]   Instrument design and characterization for high resolution MALDI-MS imaging of tissue sections [J].
Chaurand, Pierre ;
Schriver, Kenneth E. ;
Caprioli, Richard M. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (04) :476-489
[10]   Depth profiling of peptide films with TOF-SIMS and a C60 probe [J].
Cheng, J ;
Winograd, N .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3651-3659