Source localization from axial image sets by iterative relaxation of the nearest neighbor criterion

被引:20
作者
Bice, WS
Dubois, DF
Prete, JJ
Prestidge, BR
机构
[1] Univ Texas, Hlth Sci Ctr, San Antonio, TX 78229 USA
[2] Texas Prostate Brachytherapy Serv, San Antonio, TX 78229 USA
关键词
brachytherapy; localization; radioactive sources; prostate; CT; MRT; ultrasound;
D O I
10.1118/1.598717
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of axial image sets has become widely used to localize interstitial brachytherapy sources. One application of this method of localization is to perform post-implant dosimetry following transperineal interstitial permanent prostate brachytherapy (TIPPB) where the target structure and the source locations are displayed on the same image. The design of an appropriate scanning sequence often results in abutting slices of an intermediate slice width (3, 4, or 5 mm). Because a single source may be imaged on more than one slice, the resultant scans always show many more source locations than actual sources implanted. The physicist is then faced with the tedious task of determining which sources appear on more than one slice and deciding which source locations to eliminate from the data set. We have developed an algorithm, similar to one employed by Roy et al, which automates this process by relaxing the nearest neighbor criterion until the number of sources is reduced to either the number of sources implanted or the number counted on a projection radiograph. This paper details this algorithm and the results of its application to phantom studies, comparing to known source locations, as well as clinical studies, comparing to orthogonal film source localization, on a series of ten patients. Phantom studies demonstrate the superiority of the algorithm over orthogonal film reconstruction, locating 100% of the sources within 5 mm of the actual location as compared to 66% for the paired radiographs. The clinical study findings are commensurate with these results, with 72% of the sources on average located within 5 mm of the corresponding source in the other data set. The positive correlation of the quality of the orthogonal film reconstruction results with the quality of the coregistration results suggests that differences in registration between the two data sets may be due primarily to the uncertainties in the orthogonal film reconstruction. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01509-6].
引用
收藏
页码:1919 / 1924
页数:6
相关论文
共 22 条
[1]   RAPID, ACCURATE, 3-DIMENSIONAL LOCATION OF MULTIPLE SEEDS IN IMPLANT RADIOTHERAPY TREATMENT PLANNING [J].
ALTSCHULER, MD ;
FINDLAY, PA ;
EPPERSON, RD .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (11) :1305-1318
[2]   A 3-FILM TECHNIQUE FOR RECONSTRUCTION OF RADIOACTIVE SEED IMPLANTS [J].
AMOLS, HI ;
ROSEN, II .
MEDICAL PHYSICS, 1981, 8 (02) :210-214
[3]   Clinical impact of implementing the recommendations of AAPM task group 43 on permanent prostate brachytherapy using 125I [J].
Bice, WS ;
Prestidge, BR ;
Prete, JJ ;
Dubois, DF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05) :1237-1241
[4]   GEOMETRIC RECONSTRUCTION OF SEED IMPLANTS USING A 3-FILM TECHNIQUE [J].
BIGGS, PJ ;
KELLEY, DM .
MEDICAL PHYSICS, 1983, 10 (05) :701-704
[5]   Moldable tissue equivalent bolus for high-energy photon and electron therapy [J].
Dubois, D ;
Bice, W ;
Bradford, B ;
Schneid, T ;
Engelmeier, R .
MEDICAL PHYSICS, 1996, 23 (09) :1547-1549
[6]  
DUBOIS DF, 1997, INT J RADIAT ONCOL, V39, P261
[7]  
DUBOIS DF, IN PRESS MED PHYS
[8]   ANALYSIS OF ERRORS IN 3-DIMENSIONAL RECONSTRUCTION OF RADIUM IMPLANTS FROM STEREO RADIOGRAPHS [J].
FITZGERALD, LT ;
MAUDERLI, W .
RADIOLOGY, 1975, 115 (02) :455-458
[9]   COMPUTED-TOMOGRAPHY TREATMENT PLANNING IN IR-192 BRACHYTHERAPY IN THE HEAD AND NECK [J].
HAYES, JK ;
MOELLER, JH ;
LEAVITT, DD ;
DAVIS, RK ;
HARNSBERGER, HR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01) :181-189
[10]   ACCURACY OF FOREIGN BODY LOCALISATION FROM TUBE-SHIFT RADIOGRAPHS [J].
HUGHES, HA .
BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (338) :116-118