Parafac decomposition of three-way kinetic-spectrophotometric spectral matrices corresponding to mixtures of heavy metal ions

被引:28
作者
da Silva, JCGE [1 ]
Oliveira, CJS [1 ]
机构
[1] LAQUIPAI, Dept Chem, Fac Ciencias, P-4150 Porto, Portugal
关键词
kinetic-spectrophotometric data; mixtures of heavy metal ions; PARAFAC;
D O I
10.1016/S0039-9140(99)00083-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Binary and ternary mixtures of some of the following heavy metal ions Zn(II), NI(II), Pb(II), Co(II) and Cd(II) were analyzed by a ligand substitution kinetic method. Three-way data matrices were generated by acquisition of W-Vis spectra (332-580 nm) as a function of the time of a substitution reaction observed between the complex of the heavy metal ions with the non selective metallochromic indicator 4-(2-pyridylazo) resorcinol (PAR) and EDTA, and of different relative concentration of the metal ions (1-6 mM). The PARAFAC trilinear model, without restrictions, was used in the data analysis. A full decomposition of the data matrices was obtained (spectra, concentration and time profiles). It was shown that ligand substitution kinetic methods coupled to three-way chemometric analytical methods can be used for the development of robust sensors for the analysis of binary [Zn(II) + Ni(II), Pb(II) + Cd(II), Zn(II) + Pb(II)] or ternary [Zn(II) + Pb(II) + Co(II)] mixtures of metal ions in the micromolar concentration range. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:889 / 897
页数:9
相关论文
共 37 条
[1]  
[Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
[2]   STRATEGIES FOR ANALYZING DATA FROM VIDEO FLUOROMETRIC MONITORING OF LIQUID-CHROMATOGRAPHIC EFFLUENTS [J].
APPELLOF, CJ ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :2053-2056
[3]   ANALYTICAL USE OF THE KINETICS OF COMPLEX-FORMATION - SIMULTANEOUS DETERMINATION OF IRON AND COBALT BY DIFFERENTIAL KINETIC METHODS [J].
BALLESTEROS, L ;
PEREZBENDITO, D .
ANALYST, 1983, 108 (1285) :443-451
[4]   Second-order data by flow injection analysis with spectrophotometric diode-array detection and incorporated gel-filtration chromatographic column [J].
Bechmann, IE .
TALANTA, 1997, 44 (04) :585-591
[5]   PRINCIPAL COMPONENT REGRESSION FOR MIXTURE RESOLUTION IN CONTROL ANALYSIS BY UV-VISIBLE SPECTROPHOTOMETRY [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
APPLIED SPECTROSCOPY, 1994, 48 (01) :37-43
[6]   KINETIC SPECTROPHOTOMETRIC METHOD FOR ANALYZING MIXTURES OF METAL-IONS BY STOPPED-FLOW INJECTION-ANALYSIS USING PARTIAL LEAST-SQUARES REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2905-2911
[7]   KINETIC SPECTROPHOTOMETRIC DETERMINATION OF GA(III)-AL(III) MIXTURES BY STOPPED-FLOW INJECTION-ANALYSIS USING PRINCIPAL COMPONENT REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J ;
ROVIRA, E .
TALANTA, 1993, 40 (02) :261-267
[8]   ARTIFICIAL NEURAL NETWORKS FOR MULTICOMPONENT KINETIC DETERMINATIONS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4477-4483
[9]   PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :309-320
[10]   EXTENSION OF TRILINEAR DECOMPOSITION METHOD WITH AN APPLICATION TO THE FLOW PROBE SENSOR [J].
BOOKSH, KS ;
LIN, ZH ;
WANG, ZY ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2561-2569