Direct air capture of CO2 with chemicals: optimization of a two-loop hydroxide carbonate system using a countercurrent air-liquid contactor

被引:82
作者
Mazzotti, Marco [1 ]
Baciocchi, Renato [2 ]
Desmond, Michael J. [3 ]
Socolow, Robert H. [4 ]
机构
[1] Swiss Fed Inst Technol, Zurich, Switzerland
[2] Univ Roma Tor Vergata, Dept Civil Engn & Comp Sci Engn, Lab Environm Engn, Rome, Italy
[3] BP Corp NA, Naperville, IL USA
[4] Princeton Univ, Princeton, NJ 08544 USA
关键词
DIOXIDE CAPTURE;
D O I
10.1007/s10584-012-0679-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct Air Capture (DAC) of CO2 with chemicals, recently assessed in a dedicated study by the American Physical Society (APS), is further investigated with the aim of optimizing the design of the front-end section of its benchmark two-loop hydroxide-carbonate system. Two new correlations are developed that relate mass transfer and pressure drop to the air and liquid flow velocities in the countercurrent packed absorption column. These relationships enable an optimization to be performed over the parameters of the air contactor, specifically the velocities of air and liquid sorbent and the fraction of CO2 captured. Three structured Sulzer packings are considered: Mellapak-250Y, Mellapak-500Y, and Mellapak-CC. These differ in cost and pressure drop per unit length; Mellapak-CC is new and specifically designed for CO2 capture. Scaling laws are developed to estimate the costs of the alternative DAC systems relative to the APS benchmark, for plants capturing 1 Mt of CO2 per year from ambient air at 500 ppm CO2 concentration. The optimized avoided cost hardly differs across the three packing materials, ranging from $518/tCO(2) for M-CC to $568/tCO(2) for M-250Y. The $610/tCO(2) avoided cost for the APS-DAC design used M-250 Y but was not optimized; thus, optimization with the same packing lowered the avoided cost of the APS system by 7 % and improved packing lowered the avoided cost by a further 9 % The overall optimization exercise confirms that capture from air with the APS benchmark system or systems with comparable avoided costs is not a competitive mitigation strategy as long as the energy system contains high-carbon power, since implementation of Carbon Capture and Storage, substitution with low-carbon power and end-use efficiency will offer lower avoided-cost strategies.
引用
收藏
页码:119 / 135
页数:17
相关论文
共 14 条
[1]  
[Anonymous], 2011, DIR AIR CAPT CO2 CHE
[2]  
[Anonymous], NAT AMB AIR QUAL STA
[3]   Process design and energy requirements for the capture of carbon dioxide from air [J].
Baciocchi, Renato ;
Storti, Giuseppe ;
Mazzotti, Marco .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2006, 45 (12) :1047-1058
[4]   An air-liquid contactor for large-scale capture of CO2 from air [J].
Holmes, Geoffrey ;
Keith, David W. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2012, 370 (1974) :4380-4403
[5]   Economic and energetic analysis of capturing CO2 from ambient air [J].
House, Kurt Zenz ;
Baclig, Antonio C. ;
Ranjan, Manya ;
van Nierop, Ernst A. ;
Wilcox, Jennifer ;
Herzog, Howard J. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (51) :20428-20433
[6]   CO2 Capture from Dilute Gases as a Component of Modern Global Carbon Management [J].
Jones, Christopher W. .
ANNUAL REVIEW OF CHEMICAL AND BIOMOLECULAR ENGINEERING, VOL 2, 2011, 2 :31-52
[7]   Low-energy sodium hydroxide recovery for CO2 capture from atmospheric air-Thermodynamic analysis [J].
Mahmoudkhani, Maryam ;
Keith, David W. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2009, 3 (04) :376-384
[8]  
Menon A, 2011, IEAGHG 1 POSTCOMBUST
[9]   KINETICS OF REACTION BETWEEN CARBON-DIOXIDE AND HYDROXYL IONS IN AQUEOUS-ELECTROLYTE SOLUTIONS [J].
POHORECKI, R ;
MONIUK, W .
CHEMICAL ENGINEERING SCIENCE, 1988, 43 (07) :1677-1684
[10]  
Saint Gobain, 2006, NORPRO CAT CARR TYP