Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs

被引:44
作者
Oddy, MJ [1 ]
Jones, MJ [1 ]
Pendegrass, CJ [1 ]
Pilling, JR [1 ]
Wimhurst, JA [1 ]
机构
[1] Norfolk & Norwich Univ Hosp NHS Trust, Dept Orthopaed, Norwich NR4 7UZ, Norfolk, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2006年 / 88B卷 / 05期
关键词
D O I
10.1302/0301-620X.88B5.17184
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In 20 patients undergoing hybrid total hip arthroplasty, the reproducibility and accuracy of templating using digital radiographs were assessed. Digital images were manipulated using either a ten-pence coin as a marker to scale for magnification, or two digital-line methods using computer software. On-screen images were templated with standard acetate templates and compared with templating performed on hard-copy digital prints. The digital-line methods were the least reliable and accuracy of sizing compared with the inserted prostheses varied between -1.6% and +10.2%. The hard-copy radiographs showed better reproducibility than the ten-pence coin method, but were less accurate with 3.7% undersizing. The ten-pence coin method was the most accurate, with no significant differences for offset or acetabulum, and undersizing of only 0.9%. On-screen templating of digital radiographs with standard acetate templates is accurate and reproducible if a radiopaque marker such as a ten-pence coin is included when the original radiograph is taken.
引用
收藏
页码:581 / 585
页数:5
相关论文
共 13 条
[1]
Digital templating in total hip arthroplasty [J].
Bono, JV .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A :118-122
[2]
DETERMINATION OF ACCURACY OF PREOPERATIVE TEMPLATING OF NONCEMENTED FEMORAL PROSTHESES [J].
CARTER, LW ;
STOVALL, DO ;
YOUNG, TR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :507-513
[3]
CLARKE IC, 1976, CLIN ORTHOP RELAT R, P83
[4]
A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating [J].
Conn, KS ;
Clarke, MT ;
Hallett, JP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02) :269-272
[5]
The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty [J].
Della Valle, AG ;
Slullitel, G ;
Piccaluga, F ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :51-58
[6]
Eckrich S G, 1994, J Arthroplasty, V9, P419, DOI 10.1016/0883-5403(94)90053-1
[7]
*EX TOT HIP SYST, MAN OP TECHN V40
[8]
GORSKI JM, 1986, CLIN ORTHOP RELAT R, P302
[9]
Knight J L, 1992, J Arthroplasty, V7 Suppl, P403, DOI 10.1016/S0883-5403(07)80031-3
[10]
Lau Sheung-ling., 2004, RADIOGRAPHY, V10, P183