Analysis of water-soluble vitamins by high-performance liquid chromatography particle beam mass spectrometry

被引:16
作者
Careri, M [1 ]
Cilloni, R [1 ]
Lugari, MT [1 ]
Manini, P [1 ]
机构
[1] UNIV PARMA, DIPARTIMENTO FARMACEUT, I-43100 PARMA, ITALY
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 05期
关键词
D O I
10.1039/ac9963300159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Particle beam (PB) LC-MS was investigated for the analysis of eleven water-soluble vitamins, A reversed-phase chromatographic method making use of volatile buffers was set up for the simultaneous separation of this mixture by using narrow-bore columns, After optimization of the PB interface parameters, the effect of the MS source temperature was evaluated at 200 degrees C and 300 degrees C in electron impact (EI) and chemical ionization (positive-ion, PCI and negative-ion, NCI) modes, Electron impact mass spectra were library-searchable, but generally sensitivity was better under PCI conditions, Under these conditions and operating in selected-ion monitoring mode, linearity, detection limits and precision of the analysis was explored, Detection limits at the low-ng level were achieved for nicotinamide, nicotinic acid in PCI mode and pyridoxal under KCI conditions; repeatability of <6% (RSD) was obtained for all the compounds examined except for biotin.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 13 条
[1]   NEW COLUMN PACKING MATERIALS FOR SEPARATION OF WATER-SOLUBLE VITAMINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
AKIYAMA, S ;
NAKASHIMA, K ;
SHIRAKAWA, N ;
YAMADA, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1990, 63 (10) :2809-2813
[2]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY SYSTEM USING COLUMN-SWITCHING TECHNIQUES [J].
ASAKAWA, N ;
OHE, H ;
TSUNO, M ;
NEZU, Y ;
YOSHIDA, Y ;
SATO, T .
JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2) :231-241
[3]   USE OF LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY FOR THE QUANTITATION OF DETHIOBIOTIN AND BIOTIN IN BIOLOGICAL SAMPLES [J].
AZOULAY, M ;
DESBENE, PL ;
FRAPPIER, F .
JOURNAL OF CHROMATOGRAPHY, 1984, 303 (01) :272-276
[4]   DETERMINATION OF WATER-SOLUBLE VITAMINS BY LIQUID-CHROMATOGRAPHY WITH ORDINARY AND NARROW-BORE COLUMNS [J].
BLANCO, D ;
SANCHEZ, LA ;
GUTIERREZ, MD .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (07) :1525-1539
[5]   Determination of phylloquinone (vitamin K-1) by high performance liquid chromatography with UV detection and with particle beam-mass spectrometry [J].
Careri, M ;
Mangia, A ;
Manini, P ;
Taboni, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (01) :48-56
[6]  
CARERI M, 1995, J ANAL CHEM+, V351, P768
[7]  
CHASE GW, 1993, J AOAC INT, V76, P390
[8]   FORMIC-ACID AMMONIUM FORMATE BUFFER SYSTEM FOR THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
IIDA, J ;
MURATA, T .
ANALYTICAL SCIENCES, 1990, 6 (02) :269-272
[9]   APPLICATION OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY TO THE ANALYSIS OF WATER-SOLUBLE VITAMINS [J].
IIDA, J ;
MURATA, T .
ANALYTICAL SCIENCES, 1990, 6 (02) :273-276
[10]   DETERMINATION OF BIOTIN IN MULTIVITAMIN PHARMACEUTICAL PREPARATIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
KAMATA, K ;
HAGIWARA, T ;
TAKAHASHI, M ;
UEHARA, S ;
NAKAYAMA, K ;
AKIYAMA, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 356 (02) :326-330