MR-guided bone biopsy: Preliminary report of a new guiding method

被引:24
作者
Ojala, R [1 ]
Sequeiros, RB [1 ]
Klemola, R [1 ]
Vahala, E [1 ]
Jyrkinen, L [1 ]
Tervonen, O [1 ]
机构
[1] Univ Hosp Oulu, Dept Radiol, Oulu 90029, Finland
关键词
magnetic resonance imaging; interventional MRI; bone biopsy; bone neoplasms; bone diseases;
D O I
10.1002/jmri.10041
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of a new MR compatible optical tracking guided bone biopsy system. Materials and Methods: Wireless optical tracker elements were connected to a bone biopsy set. Biopsies of five different anatomic areas and lesions varying from 9 nun to 40 mm (mean 25 mm) in size, were performed. Results: We were able to perform the biopsies in all cases, and the samples allowed for a pathologic diagnosis. The procedure time was limited to less than 40 minutes, and no complications occurred. Conclusion: MR-guided bone biopsy with this new guiding system was a feasible and fast procedure that did not compromise the usability of the bone biopsy set.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 18 条
[1]   USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
NEUROSURGERY, 1993, 33 (04) :674-678
[2]   Image-guided core-needle biopsy in malignant lymphoma: Experience with 100 patients that suggests the technique is reliable [J].
BenYehuda, D ;
Polliack, A ;
Okon, E ;
Sherman, Y ;
Fields, S ;
Lebenshart, P ;
Lotan, H ;
Libson, E .
JOURNAL OF CLINICAL ONCOLOGY, 1996, 14 (09) :2431-2434
[3]  
Caversaccio M, 1999, Comput Aided Surg, V4, P328, DOI 10.1002/(SICI)1097-0150(1999)4:6<328::AID-IGS5>3.3.CO
[4]  
2-P
[5]   A whole-body registration-free navigation system for image-guided surgery and interventional radiology [J].
Jacob, AL ;
Messmer, P ;
Kaim, A ;
Suhm, N ;
Regazzoni, P ;
Baumann, B .
INVESTIGATIVE RADIOLOGY, 2000, 35 (05) :279-288
[6]   CT-guided percutaneous biopsy of sclerotic bone lesions: Diagnostic yield and accuracy [J].
Leffler, SG ;
Chew, FS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1389-1392
[7]   Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation [J].
Lewin, JS ;
Duerk, JL ;
Jain, VR ;
Petersilge, CA ;
Chao, CP ;
Haaga, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1337-1345
[8]   MR-guided bone biopsy performed with a new coaxial drill system. [J].
Neuerburg, J ;
Adam, G ;
Bucker, A ;
Zilkens, KW ;
Schmitz-Rode, T ;
Katterbach, FJ ;
Klosterhalfen, B ;
Rasmussen, E ;
van Vaals, JJ ;
Gunther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (05) :515-520
[9]   Radiologically guided bone biopsy: Results of 502 biopsies [J].
Ng, CS ;
Salisbury, JR ;
Darby, AJ ;
Gishen, P .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) :122-128
[10]  
Ojala R, 2000, J MAGN RESON IMAGING, V12, P556, DOI 10.1002/1522-2586(200010)12:4<556::AID-JMRI6>3.0.CO