Impacts of venturi turbulent mixing on the size distributions of sodium chloride and dioctyl-phthalate aerosols

被引:12
作者
Cheng, MD
Storey, JM
Wainman, T
Dam, T
机构
[1] Oak Ridge Natl Lab, Div Environm Sci, Oak Ridge, TN 37831 USA
[2] Oak Ridge Natl Lab, Engn Technol Div, Oak Ridge, TN USA
[3] Oak Ridge Associated Univ, Oak Ridge, TN USA
[4] Univ Tennessee, Dept Mech Engn, Knoxville, TN USA
关键词
aerosol; ejector; sodium chloride; dioctyl-phthalate; dilution;
D O I
10.1016/S0021-8502(01)00180-X
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this investigation was to determine if turbulent mixing created by the ejector causes change in the size distribution of particles passing through it. The results using dry solid sodium chloride (NaCl) particles show no discernible difference in the geometric mean diameter and the geometric standard deviation of particles passing through the ejector. Similar results were found for the dioctyl-phthalate (DOP) particles. In other words, there was no apparent shift in the center and spread (measured by the geometric standard deviation) of the particle size distributions. The ratio of the total number concentrations before and after the ejector indicates a dilution ratio of approximately 20 applies equally for both DOP and NaCl particles. The result suggests the dilution capability of this ejector was not affected by the particle composition. When the variability of the particle counts (in coefficient of variation, CV) in individual size ranges was examined, we found that the bin-to-bin variability was much greater for DOP than for NaCl particles. Although the first and second moments of a distribution (i.e., the geometric mean diameter and geometric standard deviation) were not altered significantly for the DOP particles by the ejector, the skewness measure indicated otherwise. The ejector may modify the particle size distribution of deformable particles such as DOP. The results suggest that it may be difficult to precisely characterize the size distribution of particles using the ejector technique if the particle is not solid. This result has an implication for the use of the ejector as a dilution tool, and one needs to know that the particles to be diluted with such a device are reasonably dry and/or non-deformable under the turbulent condition inside the ejector. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:491 / 502
页数:12
相关论文
共 8 条
[1]  
ABDULKHALEK IS, 1998, SAE SPEC PUBL, P133
[2]  
DOCKERY DW, 1996, PARTICLES OUR AIR CO
[3]  
GRASKOW BR, 1999, SAE SPEC PUBL, P151
[4]  
GRASKOW BR, 1998, SAE SPEC PUBL, P155
[5]  
Knutson E. O., 1975, Journal of Aerosol Science, V6, P443, DOI 10.1016/0021-8502(75)90060-9
[6]   Review: Epidemiological basis for particulate air pollution health standards [J].
Pope, CA .
AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (01) :4-14
[7]  
*TSI, 1999, MOD 3936 SMPS SCANN
[8]  
1997, FED REG 0718