Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery

被引:52
作者
Suzuki, Yasuyuki [1 ]
Daitoku, Kazuyuki [1 ]
Minakawa, Masahito [1 ]
Fukui, Kozo [1 ]
Fukuda, Ikuo [1 ]
机构
[1] Hirosaki Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Hirosaki, Aomori 0368562, Japan
关键词
PMEA coating; pediatric cardiac surgery; cardiopulmonary bypass; inflammatory response;
D O I
10.1007/s10047-008-0415-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Surface-coated cardiopulmonary bypass (CPB) has been shown to have excellent biocompatibility during cardiac surgery in adults, but there have been only a few reports demonstrating the efficacy of this coating for congenital cardiac surgery. We tested the efficacy of poly-2-methoxyethylacrylate (PMEA) coating for CPB circuits in congenital cardiac surgery. Eleven operative cases of ventricular septal defect were studied: group C (control: no coating, n = 5) and group P (PMEA coating, n = 6). The platelet count and beta-thromboglobulin (beta TG), fibrinogen (FBG), thrombin-antithrombin complex (TAT), and neutrophil elastase levels were measured during the operation. Postoperative chest tube drainage was analyzed and the surface of the artificial lung was observed with an electron microscope. Elevation of TAT and neutrophil elastase was suppressed in group P (P < 0.05). Observation of the artificial lung surface using an electron microscope clearly revealed fewer blood cells were adherent to the surface in group P. The FBG level and postoperative bleeding were relatively lower in group P, but there were no significant differences between groups. The platelet count and beta TG level were the same in both groups. We concluded that the PMEA-coated circuit reduces activation of the coagulation system and the inflammatory reaction in pediatric cardiac surgery.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 28 条
[1]
Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits [J].
Aldea, GS ;
Soltow, LO ;
Chandler, WL ;
Triggs, CM ;
Vocelka, CR ;
Crockett, GI ;
Shin, YT ;
Curtis, WE ;
Verrier, ED .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :742-755
[2]
Lung injury and acute respiratory distress syndrome after cardiopulmonary bypass [J].
Asimakopoulos, G ;
Smith, PLC ;
Ratnatunga, CP ;
Taylor, KM .
ANNALS OF THORACIC SURGERY, 1999, 68 (03) :1107-1115
[3]
Baykut D, 2001, EUR J MED RES, V6, P297
[4]
Phosphorylcholine or heparin coating for pediatric extracorporeal circulation causes similar biologic effects in neonates and infants [J].
Böning, A ;
Scheewe, J ;
Ivers, T ;
Friedrich, C ;
Stieh, J ;
Freitag, S ;
Cremer, JT .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (05) :1458-1465
[5]
Tissue factor as the main activator of the coagulation system during cardiopulmonary bypass [J].
De Somer, F ;
Van Belleghem, Y ;
Caes, F ;
François, K ;
Van Overbeke, H ;
Arnout, J ;
Taeymans, Y ;
Van Nooten, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (05) :951-958
[6]
Thrombin during cardiopulmonary bypass [J].
Edmunds, L. Henry, Jr. ;
Colman, Robert W. .
ANNALS OF THORACIC SURGERY, 2006, 82 (06) :2315-2322
[7]
Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children [J].
Eisses, Michael J. ;
Geiduschek, Jeremy M. ;
Jonmarker, Christer ;
Cohen, Gordon A. ;
Chandler, Wayne L. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (01) :28-34
[8]
Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass [J].
Gorman, RC ;
Ziats, NP ;
Rao, AK ;
Gikakis, N ;
Sun, L ;
Khan, MMH ;
Stenach, N ;
Sapatnekar, S ;
Chouhan, V ;
Gorman, JH ;
Niewiarowski, S ;
Colman, RW ;
Anderson, JM ;
Edmunds, LH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (01) :1-11
[9]
Impact of heparin bonding on pediatric cardiopulmonary bypass: A prospective randomized study [J].
Grossi, EA ;
Kallenbach, K ;
Chau, S ;
Derivaux, CC ;
Aguinaga, MG ;
Steinberg, BM ;
Kim, D ;
Iyer, S ;
Tayyarah, M ;
Artman, M ;
Galloway, AC ;
Colvin, SB .
ANNALS OF THORACIC SURGERY, 2000, 70 (01) :191-196
[10]
Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)-coated extracorporeal circuits [J].
Gunaydin, S ;
Farsak, B ;
Kocakulak, M ;
Sari, T ;
Yorgancioglu, C ;
Zorlutuna, Y .
ANNALS OF THORACIC SURGERY, 2002, 74 (03) :819-824