Newly developed software for capillary blood pressure analysis in microcirculatory research

被引:6
作者
Hahn, M
Klyscz, T
Shore, AC
Junger, M
机构
[1] UNIV TUBINGEN HOSP,DEPT DERMATOL,MICROVASC LAB,TUBINGEN,GERMANY
[2] UNIV EXETER,DEPT VASC RES,EXETER,DEVON,ENGLAND
来源
INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL | 1996年 / 16卷 / 03期
关键词
capillary blood pressure analysis; newly developed software; hemodynamics; pulse pressure;
D O I
10.1159/000179162
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The introduction of the servonulling technique by Wiederhielm in 1963 allowed for the first time continuous and dynamic recording of capillary blood pressure (CP). In 1979 Mahler used this technique for the first measurements in humans. Data analysis was limited to manual analysis of chart recordings. Nowadays fast analog-digital converters with ay high sampling frequency are used for data recordings, and consequently there is a need for an easy-to-use software for data analysis of CP data. The presented newly developed computer software allows analysis of mean CP, taking into account the zero pressure measured before and after capillary cannulation. The simultaneously recorded electrocardiogram R wave is used as a marker for the calculation of the mean capillary pulse pressure waves and of their characteristic data. This may help determine the significance of the capillary pulse waveform for microvascular function. Changes in the pulse waveform may be the only detectable difference between patients and healthy controls. Analysis of simultaneously recorded temperature, the display of markers for valid readings, and the possibility of excluding nonvalid data or artefacts from analysis are additional features.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 18 条
  • [1] MICROVASCULAR PRESSURES MEASURED BY MICROPUNCTURE IN LUNGS OF NEWBORN RABBITS
    FIKE, CD
    LAIFOOK, SJ
    BLAND, RD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) : 1070 - 1075
  • [2] INTAGLIETTA M, 1970, Microvascular Research, V2, P212, DOI 10.1016/0026-2862(70)90009-9
  • [3] SEGMENTAL VASCULAR-RESISTANCE DURING PULSATILE AND STEADY PERFUSION IN 3-WK-OLD TO 5-WK-OLD RABBIT LUNGS
    KAAPA, P
    RAJ, JU
    HILLYARD, R
    ANDERSON, J
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (02): : H506 - H513
  • [4] EFFECTS OF POSITION AND SKIN TEMPERATURE ON CAPILLARY PRESSURES IN FINGERS AND TOES
    LEVICK, JR
    MICHEL, CC
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1978, 274 (JAN): : 97 - +
  • [5] BLOOD-PRESSURE FLUCTUATIONS IN HUMAN NAILFOLD CAPILLARIES
    MAHLER, F
    MUHEIM, MH
    INTAGLIETTA, M
    BOLLINGER, A
    ANLIKER, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (06): : H888 - H893
  • [6] CAPILLARY PULSE WAVE-FORM IN AORTIC-STENOSIS
    MAHY, IR
    SHORE, AC
    SMITH, LDR
    TOOKE, JE
    [J]. INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1994, 14 (05): : 257 - 261
  • [7] Petrow J M, 1990, Z Gesamte Inn Med, V45, P633
  • [8] PHOLPRAMOOL C, 1984, J REPROD FERTIL, V71, P173, DOI 10.1530/jrf.0.0710173
  • [9] EFFECT OF PULSATILE FLOW ON MICROVASCULAR RESISTANCE IN ADULT-RABBIT LUNGS
    RAJ, JU
    KAAPA, P
    ANDERSON, J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (01) : 73 - 81
  • [10] RELATION OF SKIN CAPILLARY-PRESSURE IN PATIENTS WITH INSULIN-DEPENDENT DIABETES-MELLITUS TO COMPLICATIONS AND METABOLIC CONTROL
    SANDEMAN, DD
    SHORE, AC
    TOOKE, JE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (11) : 760 - 764