COMPENSATION OF EYE MOVEMENTS IN RETINAL SPECKLE FLOWMETRY USING FLEXIBLE CORRELATION ANALYSIS BASED ON THE SPECIFIC VARIANCE

被引:20
作者
Aizu, Yoshihisa [1 ]
Asakura, Toshimitsu [1 ,2 ]
Kojima, Atsushi [3 ]
机构
[1] Muroran Inst Technol, Dept Mech Syst Engn, Muroran, Hokkaido 0508585, Japan
[2] Hokkaido Univ, Res Inst Elect Sci, Sapporo, Hokkaido 0600812, Japan
[3] Kowa Co Ltd, Ghofu Lab, Ghofu, Tokyo 1820021, Japan
关键词
speckle; velocimetry; velocity measurement; speckle velocimeter; retinal blood flow; photon correlation;
D O I
10.1117/1.429878
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bio-speckle flowmetry using the photon correlation technique is useful for measuring the retinal blood flow velocity. In practical situations, however, it often suffers from eye-movement artifacts and other external moving factors. To solve this problem, we studied in this paper a flexible correlation analysis, by which the blood flow information can be effectively extracted from erroneous data influenced by displacement of the measuring point. The signal-analyzing system including the photon correlator directly stores the sequential counts of photoelectron pulses into a memory. After measurements, the stored data are read out and used to calculate the first-order statistics of time-integrated bio-speckles and the autocorrelation function with an arbitrary delay-time unit for an arbitrary period. These results are used to specify and to eliminate the erroneous parts of data due to the displacement of the measuring point. The usefulness of this technique was verified for a glass capillary model and human retinal vessels. (C) 1998 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 26 条
  • [1] MEASUREMENTS OF FLOW VELOCITY IN A MICROSCOPIC REGION USING DYNAMIC LASER SPECKLES BASED ON THE PHOTON-CORRELATION
    AIZU, Y
    AMBAR, H
    YAMAMOTO, T
    ASAKURA, T
    [J]. OPTICS COMMUNICATIONS, 1989, 72 (05) : 269 - 273
  • [2] BIO-SPECKLE PHENOMENA AND THEIR APPLICATION TO THE EVALUATION OF BLOOD-FLOW
    AIZU, Y
    ASAKURA, T
    [J]. OPTICS AND LASER TECHNOLOGY, 1991, 23 (04) : 205 - 219
  • [3] EVALUATION OF BLOOD-FLOW AT OCULAR FUNDUS BY USING LASER SPECKLE
    AIZU, Y
    OGINO, K
    SUGITA, T
    YAMAMOTO, T
    TAKAI, N
    ASAKURA, T
    [J]. APPLIED OPTICS, 1992, 31 (16): : 3020 - 3029
  • [4] Aizu Y., 1996, Bioimaging, V4, P254, DOI 10.1002/1361-6374(199612)4:4<254::AID-BIO4>3.3.CO
  • [5] 2-Z
  • [6] AIZU Y, 1994, OPT WITHIN LIFE SCI, V3, P159
  • [7] Aizu Y., 1996, Trends in Optics. Research, Development and Applications, P27
  • [8] [Anonymous], 1992, HAMAMATSU PHOTONICS
  • [9] Briers J. D., 1996, P SOC PHOTO-OPT INS, V2732, P2
  • [10] CHARACTERIZATION OF SILICON AVALANCHE PHOTODIODES FOR PHOTON-CORRELATION MEASUREMENTS .1. PASSIVE QUENCHING
    BROWN, RGW
    RIDLEY, KD
    RARITY, JG
    [J]. APPLIED OPTICS, 1986, 25 (22): : 4122 - 4126