Electrochemical high-content screening of nitric oxide release from endothelial cells

被引:31
作者
Borgmann, S [1 ]
Radtke, I [1 ]
Erichsen, T [1 ]
Blöchl, A [1 ]
Heumann, R [1 ]
Schuhmann, W [1 ]
机构
[1] Ruhr Univ Bochum, Lehrstuhl Mol Neurobiochem, D-44780 Bochum, Germany
关键词
cells; drugs; electrochemistry; nitric oxides; sensors;
D O I
10.1002/cbic.200500399
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Release of nitric oxide (NO) is of high importance for regulating endothelial cell functions during vasodilatation, vascular remodeling, and angiogenesis. Thus, a direct and reliable real-time method for NO detection that takes into account time-dependent variations of the NO concentration in the complex reaction within the diffusion zone above the cells is vital for obtaining information about the role of NO in intracellular endothelial signal transduction and its impact on the surrounding cells. In this study, the time course of vascular endothelial growth factor E (VEGF-E) stimulated NO release from transformed human umbilical vein endothelial cells (T-HUVEC) was investigated by means of metalloporphyrin-based NO sensors employed in on electrochemical robotic system. The NO sensor was obtained by electrochemically induced deposition of Ni-II tetrakis(p-nitrophenylporphyrin) on a 50-mu m diameter platinum disk electrode which was integrated, together with a 25-mu m diameter platinum disk, in a double-barrel electrode arrangement. The second electrode was used as a guidance sensor for the automatic and highly reproducible positioning of the NO sensor at a known distance from a layer of adherently growing cells by using z-approach curves in the negative feedback mode of scanning electrochemical microscopy (SECM). The electrochemical robotic system allows the fully automated detection of NO with high sensitivity and selectivity to be performed in real time within 96-well microtiter plates. A functional cell assay was established to allow the standardized detection of NO released upon stimulation from T-HUVEC with a sensor positioned at a known distance above the endothelial cells. The overall system was evaluated by automatic detection of NO release from T-HUVEC upon stimulation with VEGF-E after incubation with a variety of drugs that are known to act on different sites in the complex signal-transduction pathway that finally invokes NO release.
引用
收藏
页码:662 / 668
页数:7
相关论文
共 39 条
[1]  
[Anonymous], ANGEW CHEM
[2]   MEASUREMENT OF NITRIC-OXIDE IN BIOLOGICAL MODELS [J].
ARCHER, S .
FASEB JOURNAL, 1993, 7 (02) :349-360
[3]   Practical aspects and methodological approaches to achieve electrochemical detection of submicromolar NO in biological systems [J].
Bedioui, F ;
Trevin, S .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :227-230
[4]   Chemically modified microelectrodes designed for the electrochemical determination of nitric oxide in biological systems [J].
Bedioui, F ;
Trevin, S ;
Devynck, J .
ELECTROANALYSIS, 1996, 8 (12) :1085-1091
[5]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[6]  
Briehn CA, 2001, ANGEW CHEM INT EDIT, V40, P4680, DOI 10.1002/1521-3773(20011217)40:24<4680::AID-ANIE4680>3.0.CO
[7]  
2-X
[8]   Pyrrole functionalised metalloporphyrins as electrocatalysts for the oxidation of nitric oxide [J].
Diab, N ;
Oni, J ;
Schulte, A ;
Radtke, I ;
Blöchl, A ;
Schuhmann, W .
TALANTA, 2003, 61 (01) :43-51
[9]   Electropolymerized manganese porphyrin/polypyrrole films as catalytic surfaces for the oxidation of nitric oxide [J].
Diab, N ;
Schuhmann, W .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :265-273
[10]  
DING Y, 2002, J PHARMACOL EXP THER, V292, P606