Intravenous application of fluorescein for confocal laser scanning microscopy: evaluation of contrast dynamics and image quality with increasing injection-to-imaging time

被引:82
作者
Becker, Valentin [1 ]
von Delius, Stefan [1 ]
Bajbcouj, Monther [1 ]
Karagianni, Artemisia [1 ]
Sclunid, Roland. M. [1 ]
Meining, Alexander [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 2, Dept Internal Med 2, D-81675 Munich, Germany
关键词
D O I
10.1016/j.gie.2008.01.033
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Confocal laser scanning microscopy (CLSM) is reported to be a promising tool for in vivo histopathology during an endoscopy. The most commonly used florophore is fluorescein sodium given intravenously. However, so far, there are no objective data on contrast dynamics and image quality over time after injection of the substance. Objective: We aimed to investigate the ideal time period for the best CLSM imaging when using florescein sodium. Design: The proximal stomachs of 4 anesthetized pigs were examinee via standard endoscopes with a portable confocal miniprobe. After injection of 1% florescein intravenously (0.1 mL/kg both weight), consecutive sequences were recorded after 1, 2, 3, 5, 8, 20, 30, 40, 50, and 60 minutes. After the procedure, histograms, which represented signal intensity of 20 images (at respective time points), were analyzed from representative regions of interest (ROI). The mean (standard deviation [SD]) pixel Value of the pixel values in the ROI were noted. A signal-to-noise ratio (SNR), defined as the ratio between the mean and the SD, was calculated. In addition, 5 images per time period were put into a random order and then blindly evaluated by 2 endoscopists. Results: A total of 560 histograms from selected ROIs were analysed. The SNR decreased significantly after 8 minutes, with the lowest values being reached after 30 minutes. subjective evaluation of still images also demonstrated a continuous decrease, with the lowest image quality after 30 minutes. A slight increase of image quality after 40 minutes occured because of extramucosal leakage of fluorescein, with fluorophore deposits in the crypt orifices. Conclusions: In the pig model, flourescein-based CLSM of the GI tract delivered the best contrast and image quality within the first 8 minutes after injection of the fluorophore. These data might facilitate standardization of the procedure for research purposes but may also help when applying this new technology in a daily routine manner.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 17 条
  • [1] High-resolution miniprobe-based confocal microscopy in combination with video mosaicing (with video)
    Becker, Valentin
    Vercauteren, Tom
    von Weyhern, Claus Hann
    Prinz, Christian
    Schmid, Roland M.
    Meining, Alexander
    [J]. GASTROINTESTINAL ENDOSCOPY, 2007, 66 (05) : 1001 - 1007
  • [2] George M, 2003, ENDOSCOPY, V35, P585
  • [3] Confocal laser endoscopy for diagnosing intraepithelial neoplasias and colorectal cancer in vivo
    Kiesslich, R
    Burg, J
    Vieth, M
    Gnaendiger, J
    Enders, M
    Delaney, P
    Polglase, A
    McLaren, W
    Janell, D
    Thomas, S
    Nafe, B
    Galle, PR
    Neurath, MF
    [J]. GASTROENTEROLOGY, 2004, 127 (03) : 706 - 713
  • [4] Technology insight:: confocal laser endoscopy for in vivo diagnosis of colorectal cancer
    Kiesslich, Ralf
    Goetz, Martin
    Vieth, Michael
    Galle, Peter R.
    Neurath, Markus F.
    [J]. NATURE CLINICAL PRACTICE ONCOLOGY, 2007, 4 (08): : 480 - 490
  • [5] Chromoscopy-guided endomicroscopy increases the diagnostic yield of intraepithelial neoplasia in ulcerative colitis
    Kiesslich, Ralf
    Goetz, Martin
    Lammersdorf, Katharina
    Schneider, Constantin
    Burg, Juergen
    Stolte, Manfred
    Vieth, Michael
    Nafe, Bernhard
    Galle, Peter R.
    Neurath, Markus F.
    [J]. GASTROENTEROLOGY, 2007, 132 (03) : 874 - 882
  • [6] In vivo histology of Barrett's esophagus and associated neoplasia by confocal laser endomicroscopy
    Kiesslich, Ralf
    Gossner, Liebwin
    Goetz, Martin
    Dahlmann, Alexandra
    Vieth, Michael
    Stolte, Manfred
    Hoffman, Arthur
    Jung, Michael
    Nafe, Bernhard
    Galle, Peter R.
    Neurath, Markus F.
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2006, 4 (08) : 979 - 987
  • [7] Kim J, 2000, Curr Opin Ophthalmol, V11, P241, DOI 10.1097/00055735-200008000-00005
  • [8] Ocular fluorescein kinetics before and after vitrectomy on swine
    Knudsen, LL
    Dissing, T
    Hansen, MN
    Nielsen-Kudsk, F
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (11) : 832 - 839
  • [9] Correlation between clinical and histological features in a pig model of choroidal neovascularization
    Lassota, N
    Kiilgaard, JF
    Prause, JU
    la Cour, M
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (03) : 394 - 398
  • [10] MEINING A, 2007, ENDOSCOPY 0704