Volatile organic pollutants in new and established buildings in Melbourne, Australia

被引:162
作者
Brown, SK [1 ]
机构
[1] CSIRO Bldg Construct & Engn, Highett, Vic 3190, Australia
关键词
volatile organic compounds; formaldehyde; building materials; model; benzene; new building; indoor/outdoor;
D O I
10.1034/j.1600-0668.2002.120107.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Volatile organic compounds (VOCs) within new and established buildings have been determined and factors significant to their presence have been identified. In established dwellings, total volatile organic compound (TVOC) concentrations were low, but were approximately four times higher than in outdoor air, showing a dominant effect of indoor sources. The presence of attached garages, site contamination and 'faulty' wool carpet were associated with higher indoor pollution. In three dwellings, unidentified sources of benzene were indicated. Much higher VOC concentrations were observed in new or renovated buildings, persisting above "baseline" levels for several weeks, concentration decay rate correlating with VOC molecular volume, indicating emissions were limited by material diffusion processes. VOC and formaldehyde emission decays in a new dwelling occurred by a double-exponential source model. This shows that persistent low levels of volatile organic pollutants in established dwellings can occur due to long-term emissions from building materials.
引用
收藏
页码:55 / 63
页数:9
相关论文
共 17 条
[1]  
Brown S.K., 1997, INDOOR AIR QUALITY
[2]  
Brown S.K., 1999, ORGANIC INDOOR AIR P, P171
[3]   CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW [J].
BROWN, SK ;
SIM, MR ;
ABRAMSON, MJ ;
GRAY, CN .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :123-134
[4]   Chamber assessment of formaldehyde and VOC emissions from wood-based panels [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :209-215
[5]  
Devos M., 1990, STANDARDIZED HUMAN O
[6]  
[FISIAQ Finnish Society of Indoor Air Quality and Climate Finnish Association of Construction Clients RAKI Finnish Association of Architects/SAFA Finnish Association of Consulting Firms/SKOL], 1995, CLASS IND CLIM CONST
[7]  
GUO Z, 1996, Z 30 IND AIR QUAL SI
[8]   A review and a limited comparison of methods for measuring total volatile organic compounds in indoor air [J].
Hodgson, AT .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (04) :247-257
[9]  
HODGSON AT, 1989, ASTM STP, V1002, P244
[10]  
HOEL PG, 1947, INTRO MATH STAT, P89