Indium as internal standard in square wave anodic stripping analysis of lead in blood with microelectrode arrays

被引:31
作者
Liu, TZ [1 ]
Lai, D [1 ]
Osterloh, JD [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO GEN HOSP,MET LAB,SAN FRANCISCO,CA 94110
关键词
VOLTAMMETRY; ULTRAMICROELECTRODE; ELECTRODES;
D O I
10.1021/ac9612483
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The toxic effects of lead on humans, especially children have been well documented. ASV has been an important technique in the analysis of lead in blood of humans. This research has demonstrated that indium(III) can be used as an internal standard in the analysis of lead in blood samples with mercury film microelectrode arrays. Indium is a good choice because of a low endogenous blood concentration and because baseline separation of anodic stripping peaks among Cd, In, and Pb can be achieved under appropriate conditions. The concentration of sodium bromide strongly influences the resolution of these metals and the sensitivity of ASV to In(III) in solution. Square wave anodic stripping voltammetry together with screen-printed microelectrode arrays showed that the ratio of the anodic stripping peak currents of Pb and In varies linearly with the concentration of Pb in blood samples ranging from 1.2 to 30.0 mu g/dL. The average intraassay precision (rsd) was 6.7%.
引用
收藏
页码:3539 / 3543
页数:5
相关论文
共 22 条
[1]  
BELLINGER GA, 1993, JAMA-J AM MED ASSOC, V270, P69
[2]  
*COLL AM PATH, 1996, CAP SURV AACC CAP BL
[3]   DETERMINATION OF LEAD IN BLOOD BY SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY AT A CARBON DISK ULTRAMICROELECTRODE [J].
FELDMAN, BJ ;
OSTERLOH, JD ;
HATA, BH ;
DALESSANDRO, A .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :1983-1987
[4]  
FELDMAN BJ, 1995, CLIN CHEM, V41, P557
[5]   INTERNAL STANDARDS IN DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
FERNANDO, AR ;
KRATOCHVIL, B .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1991, 69 (04) :755-758
[6]   BLOOD LEAD AND BLOOD-PRESSURE - RELATIONSHIP IN THE ADOLESCENT AND ADULT UNITED-STATES POPULATION [J].
HARLAN, WR ;
LANDIS, JR ;
SCHMOUDER, RL ;
GOLDSTEIN, NG ;
HARLAN, LC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (04) :530-534
[7]  
HEINEMAN WR, 1984, LAB TECHNIQUES ELECT, P512
[8]   IRIDIUM-BASED ULTRAMICROELECTRODE ARRAY FABRICATED BY MICROLITHOGRAPHY [J].
KOUNAVES, SP ;
DENG, W ;
HALLOCK, PR ;
KOVACS, GTA ;
STORMENT, CW .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :418-423
[9]   ELECTROCHEMICAL SENSORS USING MICROARRAY ELECTRODES [J].
MATSUE, T .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (03) :100-108
[10]   PORT-PIRIE COHORT STUDY - ENVIRONMENTAL EXPOSURE TO LEAD AND CHILDRENS ABILITIES AT THE AGE OF 4 YEARS [J].
MCMICHAEL, AJ ;
BAGHURST, PA ;
WIGG, NR ;
VIMPANI, GV ;
ROBERTSON, EF ;
ROBERTS, RJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (08) :468-475