Accuracy of computer-automated caries detection in digital radiographs compared with human observers

被引:32
作者
Wenzel, A [1 ]
Hintze, H [1 ]
Kold, LM [1 ]
Kold, S [1 ]
机构
[1] Aarhus Univ, Fac Hlth Sci, Royal Dent Coll, Dept Oral Radiol, DK-8000 Aarhus C, Denmark
关键词
radiography; computer-assisted; diagnosis; dental caries;
D O I
10.1034/j.1600-0447.2002.21245.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare diagnostic accuracy of a caries detection program with that of human observers. A total of 190 extracted teeth were radiographed with two Trophy RVG (RadioVisioGraphy) digital sensor systems. Four observers scored the approximal surfaces in all images on a disease severity scale. Each observer thereafter used the Logicon Caries Detector (LCD) program to analyse the surfaces in the digital images and recorded their outcome. To determine the true absence or presence of caries, histological validation was used. Sensitivities, specificities, positive and negative predictive values were calculated and differences between the diagnostic methods tested. Specificities for the outcome with the LCD were significantly lower for three observers than when they themselves assessed the RVG images and, correspondingly, the positive predictive values were lower for the LCD outcome for three of the observers. Sensitivity was also lower for two observers on the diagnostic threshold caries in dentine. It was concluded that the automated caries detection program is less accurate than human observers in detecting approximal caries lesions.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 22 条
[1]   USING COMPUTERS TO DIAGNOSE AND PLAN TREATMENT OF APPROXIMAL CARIES DETECTED IN RADIOGRAPHS [J].
DUNCAN, RC ;
HEAVEN, T ;
WEEMS, RA ;
FIRESTONE, AR ;
GREER, DF ;
PATEL, JR .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (07) :873-882
[2]   The effect of a knowledge-based, image analysis and clinical decision support system on observer performance in the diagnosis of approximal caries from radiographic images [J].
Firestone, AR ;
Sema, D ;
Heaven, TJ ;
Weems, RA .
CARIES RESEARCH, 1998, 32 (02) :127-134
[3]  
GERTSMAN BB, 1998, EPIDEMIOLOGY KEPT SI, P62
[4]  
GRONDAHL HG, 1996, TXB CLIN CARDIOLOGY, P369
[5]   THE USE OF A COMPUTER-BASED IMAGE-ANALYSIS PROGRAM FOR THE DIAGNOSIS OF APPROXIMAL CARIES FROM BITEWING RADIOGRAPHS [J].
HEAVEN, TJ ;
WEEMS, RA ;
FIRESTONE, AR .
CARIES RESEARCH, 1994, 28 (01) :55-58
[6]   COMPUTER-BASED IMAGE-ANALYSIS OF NATURAL APPROXIMAL CARIES ON RADIOGRAPHIC FILMS [J].
HEAVEN, TJ ;
FIRESTONE, AR ;
FEAGIN, FF .
JOURNAL OF DENTAL RESEARCH, 1992, 71 :846-849
[7]   STEREOMICROSCOPY, FILM RADIOGRAPHY, MICRORADIOGRAPHY AND NAKED-EYE INSPECTION OF TOOTH SECTIONS AS VALIDATION FOR OCCLUSAL CARIES DIAGNOSIS [J].
HINTZE, H ;
WENZEL, A ;
LARSEN, MJ .
CARIES RESEARCH, 1995, 29 (05) :359-363
[8]   Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems [J].
Hintze, H ;
Wenzel, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) :44-49
[9]   IN-VITRO COMPARISON OF D-SPEED AND E-SPEED FILM RADIOGRAPHY, RVG, AND VISUALIX DIGITAL RADIOGRAPHY FOR THE DETECTION OF ENAMEL APPROXIMAL AND DENTINAL OCCLUSAL CARIES LESIONS [J].
HINTZE, H ;
WENZEL, A ;
JONES, C .
CARIES RESEARCH, 1994, 28 (05) :363-367
[10]  
KRAEMER HC, 1992, EVALUATING MED TESTS, P63