Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loads

被引:142
作者
Gasser, T. Christian [1 ]
Gorgulu, Goray [1 ]
Folkesson, Maggie [2 ]
Swedenborg, Jesper [2 ]
机构
[1] Royal Inst Technol KTH, Dept Solid Mech, SE-10044 Stockholm, Sweden
[2] Karolinska Univ Hosp & Inst, Dept Vasc Surg, Stockholm, Sweden
关键词
D O I
10.1016/j.jvs.2008.01.036
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: It has been suggested that mechanical failure of intraluminal thrombus (ILT) could play a key role in the rupture of abdominal aortic aneurysms (AAAs), and in the present study, this hypothesis has been investigated. An in vitro experimental approach has been proposed, which provides layer-specific failure data of ILT tissue under static and pulsatile mechanical loads. Methods. In total, 112 bone-shaped test specimens are prepared from luminal, medial, and abluminal layers of eight ILTs harvested during open elective AAA repair. Three different types of mechanical experiments, denoted as control test, ultimate strength test, and fatigue test were performed in Dulbecco's modified eagle's medium (DMEM) supplemented with fetal calf serum, L-ascorbic acid, and antibiotics at 37 degrees C and pH 7.0. In detail, fatigue tests, which are experiments, where the ILT tissue is loaded. in pulsatile manner, were carried out at three different load levels with a natural frequency of 1.0 Hz. Results. ILT's ultimate strength (156.5 kPa, 92.0 kPa, and 47.7 kPa for luminal, medial, and abluminal layers, respectively) and referential stiffness (62.88 kPa, 47.52 kPa, and 41.52 kPa, for luminal, medial, and abluminal layers, respectively) continuously decrease from the inside to the outside. ILT tissue failed within less than 1 hour under pulsatile loading at a load level of 60% ultimate strength, while a load level of about 40% ultimate strength did not cause failure within 13.9 hours. Conclusions. ILT tissue is vulnerable against fatigue failure and shows significant decreasing strength with respect to the number of load cycles. Hence, after a reasonable time of pulsating loading ILT's strength is far below its ultimate strength, and when compared with stress predictions from finite element (FE) studies, this indicates the likelihood of fatigue failure in vivo. Failure within the ILT could propagate towards the weakened vessel wall behind it and could initialize AAA failure thereafter.
引用
收藏
页码:179 / 188
页数:10
相关论文
共 37 条
[1]
Cellular content and permeability of intraluminal thrombus in abdominal aortic aneurysm [J].
Adolph, R ;
Vorp, DA ;
Steed, DL ;
Webster, MW ;
Kameneva, MV ;
Watkins, SC .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (05) :916-926
[2]
[Anonymous], 1989, PRACTICAL METHODS OP
[3]
Abdominal aortic aneurysm: Rupture associated with the high-attenuating crescent sign [J].
Arita, T ;
Matsunaga, N ;
Takano, K ;
Nagaoka, S ;
Nakamura, H ;
Katayama, S ;
Zempo, N ;
Esato, K .
RADIOLOGY, 1997, 204 (03) :765-768
[4]
Incidence and prevalence of abdominal aortic aneurysms, estimated by necropsy studies and population screening by ultrasound [J].
Bengtsson, H ;
Sonesson, B ;
Bergqvist, D .
ABDOMINAL AORTIC ANEURYSM: GENETICS, PATHOPHYSIOLOGY, AND MOLECULAR BIOLOGY, 1996, 800 :1-24
[5]
Hospital costs for elective endovascular and surgical repairs of infrarenal abdominal aortic aneurysms [J].
Bosch, JL ;
Lester, JS ;
McMahon, PM ;
Beinfeld, MT ;
Halpern, EF ;
Kaufman, JA ;
Brewster, DC ;
Gazelle, GS .
RADIOLOGY, 2001, 220 (02) :492-497
[6]
Cowin S., 2001, BONE MECH HDB
[7]
da Silva ES, 2000, CARDIOVASC SURG, V8, P526
[8]
Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: Experimental characterisation and structural static computational analysis [J].
Di Martino, E ;
Mantero, S ;
Inzoli, F ;
Melissano, G ;
Astore, D ;
Chiesa, R ;
Fumero, R .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (04) :290-299
[9]
Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk [J].
Fillinger, MF ;
Racusin, J ;
Baker, RK ;
Cronenwett, JL ;
Teutelink, A ;
Schermerhorn, ML ;
Zwolak, RM ;
Powell, RJ ;
Walsh, DB ;
Rzucidlo, EM .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) :1243-1252
[10]
Fung Y. C., 2013, BIOMECHANICS MECH PR