Development of a high-throughput quantitative assay for detecting herpes simplex virus DNA in clinical samples

被引:183
作者
Ryncarz, AJ
Goddard, J
Wald, A
Huang, ML
Roizman, B
Corey, L
机构
[1] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Med, Seattle, WA 98195 USA
[3] Univ Washington, Dept Epidemiol, Seattle, WA 98195 USA
[4] Fred Hutchinson Canc Res Ctr, Program Infect Dis, Seattle, WA 98104 USA
[5] Univ Chicago, Dept Biochem, Chicago, IL 60637 USA
[6] Univ Chicago, Dept Mol Biol, Chicago, IL 60637 USA
基金
英国惠康基金;
关键词
D O I
10.1128/JCM.37.6.1941-1947.1999
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 10(8) copies of HSV DNA/20 mu l of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2), These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a cl-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.
引用
收藏
页码:1941 / 1947
页数:7
相关论文
共 24 条
[1]   The role of laboratory investigation in the diagnosis and management of patients with suspected herpes simplex encephalitis: A consensus report [J].
Cinque, P ;
Cleator, GM ;
Weber, T ;
Monteyne, P ;
Sindic, CJ ;
vanLoon, AM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 61 (04) :339-345
[2]   EXTENDED DURATION OF HERPES-SIMPLEX VIRUS-DNA IN GENITAL LESIONS DETECTED BY THE POLYMERASE CHAIN-REACTION [J].
CONE, RW ;
HOBSON, AC ;
PALMER, J ;
REMINGTON, M ;
COREY, L .
JOURNAL OF INFECTIOUS DISEASES, 1991, 164 (04) :757-760
[3]   FREQUENT DETECTION OF GENITAL HERPES-SIMPLEX VIRUS-DNA BY POLYMERASE CHAIN-REACTION AMONG PREGNANT-WOMEN [J].
CONE, RW ;
HOBSON, AC ;
BROWN, Z ;
ASHLEY, R ;
BERRY, S ;
WINTER, C ;
COREY, L .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (10) :792-796
[4]   COAMPLIFIED POSITIVE CONTROL DETECTS INHIBITION OF POLYMERASE CHAIN-REACTIONS [J].
CONE, RW ;
HOBSON, AC ;
HUANG, MLW .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (12) :3185-3189
[5]   Rapid detection and typing of herpes simplex virus DNA in clinical specimens by the Hybrid Capture II signal amplification probe test [J].
Cullen, AP ;
Long, CD ;
Lorincz, AT .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (09) :2275-2278
[6]   A novel method for real time quantitative RT PCR [J].
Gibson, UEM ;
Heid, CA ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :995-1001
[7]   Real time quantitative PCR [J].
Heid, CA ;
Stevens, J ;
Livak, KJ ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :986-994
[8]   Evaluation of a quantitative competitive PCR assay for measuring herpes simplex virus DNA content in genital tract secretions [J].
Hobson, A ;
Wald, A ;
Wright, N ;
Corey, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (03) :548-552
[9]   DETECTION OF SPECIFIC POLYMERASE CHAIN-REACTION PRODUCT BY UTILIZING THE 5'-]3' EXONUCLEASE ACTIVITY OF THERMUS-AQUATICUS DNA-POLYMERASE [J].
HOLLAND, PM ;
ABRAMSON, RD ;
WATSON, R ;
GELFAND, DH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (16) :7276-7280
[10]   Application of the polymerase chain reaction to the diagnosis and management of neonatal herpes simplex virus disease [J].
Kimberlin, DW ;
Lakeman, FD ;
Arvin, AM ;
Prober, CG ;
Corey, L ;
Powell, DA ;
Burchett, SK ;
Jacobs, RF ;
Starr, SE ;
Whitley, RJ ;
Soong, SJ ;
Stagno, S ;
Pass, R ;
Robinson, J ;
Vaudry, W ;
Jacobs, R ;
Arvin, A ;
Prober, C ;
Bradley, J ;
Spector, S ;
Kovacs, A ;
Bryson, Y ;
Rathore, M ;
Reuman, P ;
Keyserling, H ;
Diaz, P ;
Bale, J ;
Laudert, S ;
Steele, R ;
vanDyke, R ;
Laughlin, C ;
Burchett, S ;
Meissner, C ;
deSierra, M ;
Kinney, J ;
Storch, G ;
Modlin, J ;
Weiner, L ;
Leistikow, E ;
McKinney, R ;
Kumar, M ;
Powell, D ;
Stanberry, L ;
Gruber, W ;
Sander, C ;
Demmler, G ;
Chonmaitree, T ;
Leach, C ;
Shelton, M ;
Adler, S .