Effect of dose reduction in digital dental panoramic radiography on image quality

被引:28
作者
Dannewitz, B [1 ]
Hassfeld, S [1 ]
Eickholz, P [1 ]
Mühling, J [1 ]
机构
[1] Univ Heidelberg, Sch Dent Med, Dept Oral & Maxillofacial Surg Craniofacial Surg, Heidelberg, Germany
关键词
radiography; panoramic; diagnostic imaging; radiation dosage; perception;
D O I
10.1038/sj.dmfr.4600651
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the effect of dose reduction in digital panoramic radiography on subjective image quality and diagnostic performance. Methods: Two digital panoramic radiographs were obtained with the Orthophos DS(R) (Sirona, Bensheim, Germany) of patients (n = 100) receiving dental care. The first image was taken at the standard exposure setting. For the second image the tube current was reduced by between 48 and 53%, 63 and 69%, 75 and 80% and 80 and 81% respectively. Ten observers rated both images for 21 specific anatomical details and 30 pathological findings. Results: All radiographs taken at reduced mA levels had a significantly inferior score (P<0.01) for anatomical details. There was no difference in the scores for pathological findings. Conclusion: Radiographs obtained at reduced mA had inferior subjective image quality, but there was no difference in diagnostic performance. Thus, a reduction in tube current of approximately 50% is recommended. In certain circumstances such as follow-up radiographic examinations, a reduction of up to 65% should be considered.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 16 条
[1]   HUMAN VISUAL-PERCEPTION AND ROC METHODOLOGY IN MEDICAL IMAGING [J].
CHESTERS, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1433-1476
[2]   Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography [J].
Dula, K ;
Sanderink, G ;
van der Stelt, PF ;
Mini, R ;
Buser, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (02) :227-233
[3]  
Farman A G, 2000, Dent Clin North Am, V44, P257
[4]   Charge-coupled device panoramic radiography: effect of beam energy on radiation exposure [J].
Farman, TT ;
Farman, AG ;
Kelly, MS ;
Firriolo, FJ ;
Yancey, JM ;
Stewart, AV .
DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (01) :36-40
[5]   RADIATION-DOSES OF COMMONLY USED DENTAL RADIOGRAPHIC SURVEYS [J].
FREEMAN, JP ;
BRAND, JW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 77 (03) :285-289
[6]   DIGITAL RADIOGRAPHY [J].
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (07) :751-784
[7]  
HASSFELD S, 1997, ZAHNARZTL WELT, V106, P510
[8]   A comparison of the response of storage phosphor and film radiography to small variations in X-ray exposure [J].
Hildebolt, CF ;
Fletcher, G ;
YokoyamaCrothers, N ;
Conover, GL ;
Vannier, MW .
DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (03) :147-151
[9]   Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions .2. Effects on diagnostic accuracy after application of image processing [J].
Kullendorff, B ;
Nilsson, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 82 (05) :585-589
[10]   SENS-A-RAY - A NEW SYSTEM FOR DIRECT DIGITAL INTRAORAL RADIOGRAPHY [J].
NELVIG, P ;
WING, K ;
WELANDER, U .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1992, 74 (06) :818-823