Effect of artifacts due to flowing blood on the reproducibility of phase-contrast measurements of myocardial motion

被引:25
作者
Drangova, M [1 ]
Zhu, YD [1 ]
Pelc, NJ [1 ]
机构
[1] STANFORD UNIV,RICHARD M LUCAS CTR MR IMAGING & SPECT,DEPT RADIOL,STANFORD,CA 94305
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 04期
关键词
myocardial motion measurement; cine phase contrast producibility; presaturation; ghost artifacts;
D O I
10.1002/jmri.1880070409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The reproducibility of myocardial motion trajectories calculated from cine phase-contrast (PC) velocity data is reduced by artifacts due to the inconsistent motion of intracardiac blood. Spatial presaturation reduces these artifacts but requires a longer sequence TR, with a potentially negative effect on trajectory accuracy and reproducibility. We investigated the effect of spatial presaturation on trajectory reproducibility. A midventricular transaxial slice was imaged in five normal volunteers, The same slice was imaged three times each with sequences using spatial presaturation or not, Because the most serious artifacts originate in the heart chambers and propagate in the phase-encoded direction, myocardial regions that were in line with the heart chambers (in the phase-encode direction) had the highest artifact level in the scans without spatial presaturation. The reproducibility of trajectories for regions placed in these areas (the anterior wall, septum and posterior wall in the transaxial scans with phase encoding in the anterior-posterior direction) improved by a factor of two when presaturation was used (P < .001). In areas that were not in line with the heart chambers (eg, the anterior aspect of the lateral wall in the transaxial scans), the effect of presaturation was not significant. These results correlate well with the measured reduction in artifact level. The reproducibility of myocardial motion trajectories over large areas of the heart is improved to approximately 1 mm when presaturation is used, Therefore, use of presaturation is recommended for myocardial motion studies using cine PC velocity data.
引用
收藏
页码:664 / 668
页数:5
相关论文
共 5 条
[1]  
DRANGOVA M, 1994, P SMR 2 ANN M, P1476
[2]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[3]  
LIAO JR, 1995, P 3 ANN SCI M SOC MA, P744
[4]   TRACKING OF CYCLIC MOTION WITH PHASE-CONTRAST CINE MR VELOCITY DATA [J].
PELC, NJ ;
DRANGOVA, M ;
PELC, LR ;
ZHU, Y ;
NOLL, DC ;
BOWMAN, BS ;
HERFKENS, RJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03) :339-345
[5]  
ZHU Y, 1996, J MAGN RESON IMAGING, V35, P471