Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast

被引:39
作者
Brookes, JA [1 ]
Redpath, TW [1 ]
Gilbert, FJ [1 ]
Needham, G [1 ]
Murray, AD [1 ]
机构
[1] UNIV ABERDEEN,DEPT RADIOL,ABERDEEN AB9 2ZD,SCOTLAND
关键词
D O I
10.1259/0007-1285-69-819-206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using a variable flip angle gradient refocused imaging technique. dynamic quantitative T-1 relaxation maps acquired before and after the administration of a gadolinium contrast bolus enable the concentration-time curve of the paramagnetic agent in breast tissue to be calculated. This imaging technique has the aim of improving the diagnostic accuracy of MR mammography. Measurements with phantoms of calibrated T-1 values have been carried out to investigate the accuracy of the method, with particular reference to errors caused by incomplete spoiling of residual transverse magnetization and inaccurate radio frequency (RF) flip-angle settings. A clinical example is presented. The method has potential use for any patient study which necessitates rapid quantitation of changing in vivo T-1 values as a result of contrast agent injection.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 19 条
[1]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[2]   TUMOR RECURRENCE VERSUS FIBROSIS IN THE IRRADIATED BREAST - DIFFERENTIATION WITH DYNAMIC GADOLINIUM-ENHANCED MR-IMAGING [J].
DAO, TH ;
RAHMOUNI, A ;
CAMPANA, F ;
LAURENT, M ;
ASSELAIN, B ;
FOURQUET, A .
RADIOLOGY, 1993, 187 (03) :751-755
[3]   DIFFERENTIATION OF BENIGN FROM MALIGNANT BREAST MASSES BY TIME-INTENSITY EVALUATION OF CONTRAST-ENHANCED MRI [J].
FLICKINGER, FW ;
ALLISON, JD ;
SHERRY, RM ;
WRIGHT, JC .
MAGNETIC RESONANCE IMAGING, 1993, 11 (05) :617-620
[4]   RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING [J].
FRAM, EK ;
HERFKENS, RJ ;
JOHNSON, GA ;
GLOVER, GH ;
KARIS, JP ;
SHIMAKAWA, A ;
PERKINS, TG ;
PELC, NJ .
MAGNETIC RESONANCE IMAGING, 1987, 5 (03) :201-208
[5]   MR-IMAGING OF THE BREAST WITH ROTATING DELIVERY OF EXCITATION OFF RESONANCE - CLINICAL-EXPERIENCE WITH PATHOLOGICAL CORRELATION [J].
HARMS, SE ;
FLAMIG, DP ;
HESLEY, KL ;
MEICHES, MD ;
JENSEN, RA ;
EVANS, WP ;
SAVINO, DA ;
WELLS, RV .
RADIOLOGY, 1993, 187 (02) :493-501
[6]   FAT-SUPPRESSED 3-DIMENSIONAL MR IMAGING OF THE BREAST [J].
HARMS, SE ;
FLAMIG, DP ;
HESLEY, KL ;
EVANS, WP ;
CHEEK, JH ;
PETERS, GN ;
KNOX, SM ;
SAVINO, DA ;
NETTO, GJ ;
WELLS, RB ;
JONES, SE .
RADIOGRAPHICS, 1993, 13 (02) :247-267
[7]   MR IMAGING OF THE BREAST [J].
HARMS, SE ;
FLAMIG, DP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :277-283
[8]  
Harms Steven E., 1992, Magnetic Resonance Quarterly, V8, P139
[9]   METHOD FELL THE QUANTITATIVE ASSESSMENT OF CONTRAST AGENT UPTAKE IN DYNAMIC CONTRAST-ENHANCED MRT [J].
HITTMAIR, K ;
GOMISCEK, G ;
LANGENBERGER, K ;
RECHT, M ;
IMHOF, H ;
KRAMER, J .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :567-571
[10]   DRIVEN-EQUILIBRIUM SINGLE-PULSE OBSERVATION OF T1 RELAXATION - A REEVALUATION OF A RAPID NEW METHOD FOR DETERMINING NMR SPIN-LATTICE RELAXATION-TIMES [J].