Joint line reconstruction in medial unicompartmental knee arthroplasty: development and validation of a measurement method

被引:24
作者
Weber, Patrick [1 ]
Schroeder, Christian [1 ]
Laubender, Rudiger Paul [2 ]
Baur-Melnyk, Andrea [3 ]
Pellengahr, Christoph von Schulze [4 ]
Jansson, Volkmar [1 ]
Mueller, Peter E. [1 ]
机构
[1] Univ Munich, Dept Orthopaed Surg, D-81377 Munich, Germany
[2] Univ Munich, Inst Med Informat Biometry & Epidemiol, D-81377 Munich, Germany
[3] Univ Munich, Inst Clin Radiol, Klinikum Grosshadern, D-81377 Munich, Germany
[4] Ruhr Univ Bochum, St Josef Hosp, Dept Orthopaed Surg, D-44791 Bochum, Germany
关键词
Joint line; Unicondylar knee arthroplasty; Implant positioning; REPLACEMENT; AGREEMENT; POSITION; TKA;
D O I
10.1007/s00167-013-2617-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Preservation of the joint line in total knee arthroplasty (TKA) has shown to be an important factor for the long-term outcome, especially in revision TKA. For unicompartmental knee arthroplasty (UKA), the role of the joint line has neither been investigated nor is it consciously respected during implantation. Thus, the aim was to establish and validate a standardised measurement method to determine the joint line in UKA. As there is no established method to evaluate changes in the joint line radiologically, we introduced two methods and correlated them. The methods were first validated in a cadaver model by a controlled rotational study. Then, the joint line of 29 patients with an UKA (Oxford, Biomet, Bridgend, UK) was determined on pre- and post-operative radiographs. Both methods were tested by intra- and inter-rater reliability. Both methods showed a good intra- and inter-rater reliability. Furthermore, there was only little bias in agreement between both methods and raters. Measurements of the 29 UKA patients revealed that the joint line was more distally by a mean of 4.4 +/- A 1.2 mm after surgery. The study provides for the first time a reliable and standardised measurement tool to determine the changes in the joint line after implantation of an UKA. The instrument should be used in further studies to evaluate the impact of the joint line on the long-term outcome, the load in the two non-replaced knee compartments and on the ligaments. Diagnostic study without a universally applied 'gold' standard, Level III.
引用
收藏
页码:2468 / 2473
页数:6
相关论文
共 22 条
[1]
Patella baja after unicompartmental knee arthroplasty [J].
Anagnostakos, Konstantinos ;
Lorbach, Olaf ;
Kohn, Dieter .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (08) :1456-1462
[2]
[Anonymous], 2014, R LANG ENV STAT COMP
[3]
Restoring the joint line in revision TKA: does it matter? [J].
Bellemans, J .
KNEE, 2004, 11 (01) :3-5
[4]
NEW METHOD OF MEASURING PATELLAR HEIGHT [J].
BLACKBURNE, JS ;
PEEL, TE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (02) :241-242
[5]
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[6]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]
Carstensen B., Int J Biostat, DOI DOI 10.2202/1557-4679.1107
[8]
CATON J, 1982, REV CHIR ORTHOP, V68, P317
[9]
Classen T, 2009, RADIOLOGE, V49, P533, DOI 10.1007/s00117-009-1885-0
[10]
Fixed-bearing unicompartmental knee arthroplasty. Patients' selection and operative technique [J].
Deschamps, G. ;
Chol, C. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (06) :648-661