Interaction of volatile organic compounds with indoor materials -: a small-scale screening method

被引:63
作者
Meininghaus, R
Salthammer, T
Knöppel, H
机构
[1] Commiss European Communities, Inst Environm, I-21020 Ispra, Italy
[2] Fraunhofer Inst Wood Res, D-38108 Braunschweig, Germany
关键词
indoor air; mass transport; permeability; sink; FLEC;
D O I
10.1016/S1352-2310(98)00367-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air pollution caused by volatile organic compounds (VOCs) may affect the health and well-being of inhabitants. Uptake and release of these compounds by and from indoor materials alter their concentrations in indoor air: uptake will lower peak concentrations, whereas subsequent (slow) release at lower concentration levels will prolong the presence of VOCs in indoor air. An experimental set-up has been implemented where indoor materials are placed as a "membrane" separating two air compartments. Both compartments - consisting of Field and Laboratory Emission Cells FLECs - are constantly hushed with air, one air stream containing a mixture of 20 VOCs, and concentrations in both compartments are measured after 1 h. Ten materials usually covering extensive surfaces indoors were consecutively exposed to the vapour mixture at concentration levels typically found in indoor environments. Under the chosen experimental conditions, five of these materials exhibited a permeability high enough that VOCs could be detected on the other side. Mass transport of VOCs into and through indoor materials has therefore been confirmed by experiment. The set-up allows for a quick screening of indoor materials with respect to their sorption capacity and permeability. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2395 / 2401
页数:7
相关论文
共 21 条
[2]  
Berglund B., 1992, Indoor Air, V2, P2, DOI [10.1111/j.1600-0668.1992.02-21.x, DOI 10.1111/J.1600-0668.1992.02-21.X]
[3]   CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW [J].
BROWN, SK ;
SIM, MR ;
ABRAMSON, MJ ;
GRAY, CN .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :123-134
[4]  
Colombo A., 1991, INDOOR AIR, V1, P13, DOI DOI 10.1111/j.1600-0668.1991.02-11.x
[5]  
Colombo A., 1993, Indoor Air, V3, P276, DOI [DOI 10.1111/J.1600-0668.1993.00009.X, 10.1111/j.1600-0668.1993.00009.x]
[6]  
De Bortoli M., 1986, ENVIRON INT, V12, P343, DOI [DOI 10.1016/0160-4120(86)90048-6, 10.1016/0160-4120(86)90048-6]
[7]  
DEBORTOLI M, 1996, ASTM STP, V1287
[8]  
DUNN JE, 1993, AM SOC TEST MATER, V1205, P64, DOI 10.1520/STP13100S
[9]   COMPENSATING FOR SINK EFFECTS IN EMISSIONS TEST CHAMBERS BY MATHEMATICAL-MODELING [J].
DUNN, JE ;
TICHENOR, BA .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (05) :885-894
[10]  
JORGENSEN RB, 1993, INDOOR AIR 93, V2, P383