Influence of systolic-pressure-variation-guided intraoperative fluid management on organ function and oxygen transport

被引:82
作者
Buettner, M. [2 ]
Schummer, W. [2 ]
Huettemann, E. [2 ]
Schenke, S. [3 ]
van Hout, N. [2 ]
Sakka, S. G. [1 ]
机构
[1] Univ Witten Herdecke, Dept Anaesthesiol & Intens Care Med, Med Ctr Cologne Merheim, D-51109 Cologne, Germany
[2] Hosp Worms, Dept Anaesthesiol & Intens Care Med, Worms, Germany
[3] Univ Jena, Dept Informat, Jena, Germany
关键词
arterial pressure; measurement; complications; multiple organ dysfunction syndrome; fluid; balance; heart; myocardial function; monitoring; intraoperative; surgery; abdominal;
D O I
10.1093/bja/aen126
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Dynamic variables, for example, systolic pressure variation (SPV), are superior to filling pressures for assessing fluid responsiveness. We analysed the effects of SPV-guided intraoperative fluid management on organ function and perfusion when compared with routine care. Methods. Eighty patients (44 female and 36 male) undergoing elective major abdominal surgery were randomly assigned to a control group [n=40, mean age 66 (SD 10), range 40-84 yr] or SPV group [n=40, age 61 (16), range 26-100 yr] in which intraoperative fluid management was guided by SPV (trigger: SPV > 10%). Central venous O(2) saturation (ScvO(2)), lactate and bilirubin, creatinine, indocyanine green plasma disappearance rate (ICG-PDR), and gastric mucosal CO(2) tension were measured after induction of anaesthesia, after 3, 6, 12, and 24 h. Results. Patient characteristics, duration of surgery [5.8 (2.5) vs 5.4 (2.5) h], and infusion volumes (median 4865 vs 4330 ml) were comparable between the groups. At 3 and 6 h, SPV (P=0.04, P=0.01) and Delta down (P=0.005, P=0.01) were significantly higher in the control group. Oxygen transport and organ function were comparable: baseline and 24 h values for ICG-PDR: 28.5 (7.9) and 22.7 (7.8) vs 23.9 (6.9) and 26.1 (5.9)% min(-1), 77.7 (6.6) and 72.6 (5.5) vs 79.3 (7.1) and 72.8 (6.7)% for ScvO(2) and 1.0 (0.4) and 1.2 (0.6) vs 0.9 (0.2) and 1.3 (0.5) mmol litre(-1) for lactate. Length of mechanical ventilation, ICU stay, and mortality were comparable. Conclusions. In comparison with routine care, intraoperative SPV-guided treatment was associated with slightly increased fluid adminstration whereas organ perfusion and function was similar.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 24 条
[1]   Achieving the goal [J].
Boyd, O ;
Bennett, ED .
CRITICAL CARE MEDICINE, 1999, 27 (10) :2298-2299
[2]   Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery [J].
Conway, DH ;
Mayall, R ;
Abdul-Latif, MS ;
Gilligan, S ;
Tackaberry, C .
ANAESTHESIA, 2002, 57 (09) :845-849
[3]  
DEITCH EA, 1990, ARCH SURG-CHICAGO, V125, P403
[4]   Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery [J].
Gan, TJ ;
Soppitt, A ;
Maroof, M ;
El-Moalem, H ;
Robertson, KM ;
Moretti, E ;
Dwane, P ;
Glass, PSA .
ANESTHESIOLOGY, 2002, 97 (04) :820-826
[5]  
Gan TJ, 1997, BRIT MED J, V315, P893
[6]   Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients [J].
Goepfert, Matthias S. G. ;
Reuter, Daniel A. ;
Akyol, Derya ;
Lamm, Peter ;
Kilger, Erich ;
Goetz, Alwin E. .
INTENSIVE CARE MEDICINE, 2007, 33 (01) :96-103
[7]   Validation of air tonometric measurement of gastric regional concentrations of CO2 in critically ill septic patients [J].
Heinonen, PO ;
Jousela, IT ;
Blomqvist, KA ;
Olkkola, KT ;
Takkunen, OS .
INTENSIVE CARE MEDICINE, 1997, 23 (05) :524-529
[8]   Perioperative fluid management: comparison of high, medium and low fluid volume on tissue oxygen pressure in the small bowel and colon [J].
Hiltebrand, L. B. ;
Pestel, G. ;
Hager, H. ;
Ratnaraj, J. ;
Sigurdsson, G. H. ;
Kurz, A. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (11) :927-933
[9]   Increased gastric PCO2 during exercise is indicative of gastric ischaemia:: a tonometric study [J].
Kolkman, JJ ;
Groeneveld, ABJ ;
van der Berg, FG ;
Rauwerda, JA ;
Meuwissen, SGM .
GUT, 1999, 44 (02) :163-167
[10]   Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients [J].
Lefrant, JY ;
Bruelle, P ;
Aya, AGM ;
Saissi, G ;
Dauzat, M ;
de La Coussaye, JE ;
Eledjam, JJ .
INTENSIVE CARE MEDICINE, 1998, 24 (04) :347-352