renal function; glomerular filtration rate; MR renography; tracer kinetics; gadolinium chelates; compartmental modeling; CONTRAST-ENHANCED MRI; SINGLE KIDNEY-FUNCTION; PATLAK PLOT TECHNIQUE; RENAL-FUNCTION; DYNAMIC MRI; NONINVASIVE MEASUREMENT; QUANTITATIVE ASSESSMENT; FUNCTIONAL ASSESSMENT; EXTRACTION FRACTION; MAGNETIC-RESONANCE;
D O I
10.1002/jmri.21642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To compare six methods for calculating the single-kidney glomerular filtration rate (GFR) from T(1)-weighted magnetic resonance (MR) renography (MRR) against reference radionuclide measurements. Materials and Methods: In 10 patients, GFR was determined using six published methods: the Baumann-Rudin model (BR), the Patlak-Rutland method (PR), the two-compartment model without bolus dispersion (2C) and with dispersion (2CD), the three-compartment model (3CD), and the distributed parameter model (3C-IRF). Reference single-kidney GFRs were measured by radionuclide renography. The coefficient of variation of GFR (CV) was determined for each method by Monte Carlo analyses for one healthy and one dysfunctional kidney at a noise level (sigma(n)) of 2%, 5%, and 10%. Results: GFR estimates in patients varied from 6% overestimation (BR) to 50% underestimation (PR and 2CD applied to cortical data). Correlations with reference GFRs ranged from R = 0.74 (2CD, cortical data) to R = 0.85 (BR). In simulations, the lowest CV was produced by 3C-IRF in healthy kidney (1.7 sigma(n)) and by PR in diseased kidney. 2.4)sigma(n)). In both kidneys the highest CV was obtained wit 2CD ((5.9-8.2)sigma(n)) and with 3CD in diseased kidney (8.9 sigma(n) at sigma(n) = 10%). Conclusion: GFR estimates depend on the renal model and type of data used. Two and three-compartment models produce comparable GFR correlations.
引用
收藏
页码:371 / 382
页数:12
相关论文
共 33 条
[1]
Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[2]
Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI [J].
Baumann, D ;
Rudin, M .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :587-595
[3]
Single breath-hold T1 measurement using low flip angle TrueFISP [J].
Bokacheva, L ;
Huang, AJ ;
Chen, Q ;
Oesingmann, N ;
Storey, P ;
Rusinek, H ;
Lee, VS .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1186-1190
[4]
Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies [J].
Bokacheva, Louisa ;
Rusinek, Henry ;
Chen, Qun ;
Oesingmann, Niels ;
Prince, Chekema ;
Kaur, Manmeen ;
Kramer, Elissa ;
Lee, Vivian S. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1012-1018
[5]
Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements:: A phase I trial [J].
Boss, Andreas ;
Martirosian, Petros ;
Gehrmann, Michael ;
Artunc, Ferruh ;
Risler, Teut ;
Oesingmann, Niels ;
Claussen, Claus D. ;
Schick, Fritz ;
Kueper, Klaus ;
Schlemmer, Heinz-Peter .
RADIOLOGY, 2007, 242 (03) :783-790
[6]
Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects [J].
Buckley, David L. ;
Shurrab, Ala'a E. ;
Cheung, Ching M. ;
Jones, Andrew P. ;
Mamtora, Hari ;
Kalra, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1117-1123
[7]
Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal artery stenoses [J].
Coulam, CH ;
Lee, JH ;
Wedding, KL ;
Spielman, DM ;
Pelc, NJ ;
Kee, ST ;
Hill, BB ;
Bouley, DM ;
Derby, GC ;
Myers, BD ;
Sawyer-Glover, AM ;
Sommer, FG .
RADIOLOGY, 2002, 223 (01) :76-82
[8]
Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs [J].
Daghini, Elena ;
Juillard, Laurent ;
Haas, John A. ;
Krier, James D. ;
Romero, Juan C. ;
Lerman, Lilach O. .
RADIOLOGY, 2007, 242 (02) :417-424
[9]
de Priester JA, 2000, J MAGN RESON IMAGING, V12, P453, DOI 10.1002/1522-2586(200009)12:3<453::AID-JMRI11>3.0.CO
[10]
2-Z