A comparison of the use of an ATP-based bioluminescent assay and image analysis for the assessment of bacterial adhesion to standard HEMA and biomimetic soft contact lenses

被引:30
作者
Andrews, CS
Denyer, SP
Hall, B
Hanlon, GW
Lloyd, AW
机构
[1] Univ Brighton, Sch Pharm & Biomol Sci, Biomed Mat Res Grp, Brighton BN2 4GJ, E Sussex, England
[2] Biocompatibles Ltd, Eye Care Div, Farnham GU9 8QL, Surrey, England
关键词
soft contact lenses; bacterial adhesion; Pseudomonas aeruginosa; Staphylococcas epidermidis; Serratia marcescens; biomimetic; phosphorylcholine; bioluminescent ATP assay; image analysis;
D O I
10.1016/S0142-9612(01)00160-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate in vitro adhesion of clinically relevant bacteria to standard HEMA and novel biomimetic soft contact lenses (SCL) using bioluminescent ATP assay and image analysis. Unworn SCL were incubated with Pseudomonas aeruginosa, Staphylococcus epidermidis or Serratia marcescens suspended in sterile phosphate buffered saline (PBS). The level of bacterial adhesion after 1, 2, 4, 6 and 18 h, was assessed using both image analysis and a bioluminescent ATP assay. Species differences in the overall level of adhesion to the different types of lens were observed using both measurement techniques. Generally bacterial adhesion was shown to peak at 4-6 h, then decline to a much lower level by 18 h. After 4 h, adhesion of all species of bacteria to the biomimetic SCL (omafilcon A) was found to be significantly lower than to the standard HEMA SCL (polymacon) (p < 0.05, Student's t-test, n = 4). Both these techniques demonstrated that novel biomimetic SCL materials exhibit significantly lower bacterial adhesion in vitro compared to standard HEMA SCL materials. SCL manufactured with these novel biomimetic materials may reduce the risk of infection. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3225 / 3233
页数:9
相关论文
共 22 条
[1]  
Cowell BA, 1998, J APPL MICROBIOL, V84, P950
[2]  
Denyer S. P., 1989, ATP Luminescence. Rapid methods in microbiology., P189
[3]  
ELDER M, 1993, PRACTITIONER, V273, P509
[4]   Microbial contamination of hydrogel contact lenses [J].
Gopinathan, U ;
Stapleton, F ;
Sharma, S ;
Willcox, MDP ;
Sweeney, DF ;
Rao, GN ;
Holden, BA .
JOURNAL OF APPLIED MICROBIOLOGY, 1997, 82 (05) :653-658
[5]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[6]   BIOMEMBRANES AS MODELS FOR POLYMER SURFACES .5. THROMBOELASTOGRAPHIC STUDIES OF POLYMERIC LIPIDS AND POLYESTERS [J].
HALL, B ;
BIRD, RL ;
KOJIMA, M ;
CHAPMAN, D .
BIOMATERIALS, 1989, 10 (04) :219-224
[7]   BIOMEMBRANE SURFACES AS MODELS FOR POLYMER DESIGN - THE POTENTIAL FOR HEMOCOMPATIBILITY [J].
HAYWARD, JA ;
CHAPMAN, D .
BIOMATERIALS, 1984, 5 (03) :135-142
[8]  
Holden Brien A., 1996, CLAO Journal, V22, P47
[9]   Effect of tear-specific immunoglobulin A on the adhesion of Pseudomonas aeruginosa I to contact lenses [J].
Lan, J ;
Willcox, MDP ;
Jackson, GDF .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1999, 27 (3-4) :218-220
[10]  
Liesegang TJ, 1997, CORNEA, V16, P125