Use of GPS ASHTECH Z12T receivers for accurate time and frequency comparisons

被引:18
作者
Petit, G [1 ]
Thomas, C
Jiang, ZH
Uhrich, P
Taris, F
机构
[1] Bur Int Poids & Mesures, Sevres, France
[2] BNM, Lab Primaire Temps & Frequences, Paris, France
关键词
D O I
10.1109/58.775661
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The GPS phase measurements described in this paper were obtained using two similar multichannel GPS ASHTECH Z12T receivers belonging to the Bureau International des Folds et Mesures, BIPM, and the Laboratoire Primaire du Temps et des Frequences, BNM-LPTF. These receivers are based on the conventional geodetic ASHTECH Z12 unit, which has been modified to meet the stability requirements of time and frequency comparisons. Comparison of the two receivers operated side by side in different antenna configurations shows typical short-term. noise of 1.1 to 3.5 ps. Longer term variations indicate a temperature sensitivity in the equipment, which limits the performance of the GPS phase method. One of the receivers was successfully operated using a temperature-stabilized antenna TSA from 3S Navigation, and the ASHTECH antenna, which feeds the second receiver, was placed in a home-built oven maintained at a constant temperature. These precautions made it possible to reduce a number of systematic effects. A separate study of frequency comparison was carried out between two hydrogen-masers located at the BNM-LPTF (Paris, France) and the PTB (Braunschweig, Germany) using receivers similar to ASHTECH Z12T receivers. The relative frequency stability obtained was about 3.3 X 10(-15) for an average time of 15 000 s, an interesting result comparable with the outstanding performance of new ultrastable frequency standards.
引用
收藏
页码:941 / 949
页数:9
相关论文
共 11 条
[1]   Laser-cooled mercury ion frequency standard [J].
Berkeland, DJ ;
Miller, JD ;
Bergquist, JC ;
Itano, WM ;
Wineland, DJ .
PHYSICAL REVIEW LETTERS, 1998, 80 (10) :2089-2092
[2]  
CLAIRON A, 1998, COMMUNICATION MAY
[3]  
DOUGLAS RJ, 1994, P 26 PTTI REST VA, P141
[4]  
Dunn C., 1993, P 25 PREC TIM TIM IN, P169
[5]  
Larson K.M., 1997, P 29 PTTI LONG BEACH, P221
[6]  
LEWANDOWSKI W, 1997, P 11 EUR FREQ TIM FO, P498
[7]  
Overney F., 1998, P 12 EUR FREQ TIM FO, P94
[8]  
OVERNEY F, 1997, P 11 EUR FREQ TIM FO, P504
[9]   GPS frequency transfer using carrier phase measurements [J].
Petit, G ;
Thomas, C .
PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), 1996, :1151-1158
[10]  
PETIT G, 1997, P 11 EUR FREQ TIM FO, P336