Evaluation of a new Sebia kit for analysis of hemoglobin fractions and variants on the Capillarys® system

被引:26
作者
Louahabi, A [1 ]
Philippe, M [1 ]
Lali, S [1 ]
Wallemacq, P [1 ]
Maisin, D [1 ]
机构
[1] St Luc Univ Hosp, Dept Clin Chem, B-1200 Brussels, Belgium
关键词
Capillarys (R); capillary zone electrophoresis; hemoglobinopathies; thalassemia;
D O I
10.1515/CCLM.2006.059
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We evaluated the analytical performances of the new Sebia kit for quantification of hemoglobin fractions (HbA, HbF and HbA(2)) and structural hemoglobin variants on the Capillarys(R) system. This automated capillary zone electrophoresis method uses an alkaline buffer with silica capillaries and spectrophotometric detection. Specimen stability was evaluated during 1 month. The reproducibility of migration and the imprecision of quantification were also investigated. Comparison with the Beckman P/ACE(R) system was performed on 202 samples. A total of 131 subjects without any hematological abnormality were analyzed to establish the HbA2 reference ranges based on our local population. Quantification of the Hb fractions and variants exhibited excellent stability for 4 weeks of storage at 4 degrees C, with CVs < 0.3%. The imprecision of the migration normalized to that of HbA2 for all hemoglobins tested ( fractions and variants) was low, with a CV of < 2.5%. At physiological and pathological levels, total imprecision ranged from 1.9% to 4.6% for HbA(2), from 0.6% to 9.7% for HbF, and from 0.6% to 1% for HbS. Statistical analysis revealed a small proportional negative bias for HbA(2) (-8.6%). Small systematic bias (-0.2%) and proportional bias (-28%) were observed for HbF. No statistically significant difference was found for HbS. The reference range for HbA(2) was 2.1 - 3.2%. The Capillarys(R) system is a fully automated and accurate system that gives high-resolution performance and displays appropriate characteristics for use as a routine method for the diagnosis of thalassemias and hemoglobinopathies.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 18 条
[1]  
BHAVNANI M, 1994, J CLIN PATHOL, V47, P199
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BURTIS CA, 1999, TIETZ TXB CLIN CHEM, P265
[4]  
Clarke GM, 2000, CLIN CHEM, V46, P1284
[5]  
Cotton F, 1999, CLIN CHEM, V45, P237
[6]  
Hedlund B., 1980, HEMOGLOBINOPATHIES T, P14
[7]  
Hollis S, 1996, ANN CLIN BIOCHEM, V33, P1
[8]   Capillary electrophoresis of hemoglobin [J].
Jenkins, M ;
Ratnaike, S .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (06) :747-754
[9]   HPLC retention time as a diagnostic tool for hemoglobin variants and hemoglobinopathies: A study of 60,000 samples in a clinical diagnostic laboratory [J].
Joutovsky, A ;
Hadzi-Nesic, J ;
Nardi, MA .
CLINICAL CHEMISTRY, 2004, 50 (10) :1736-1747
[10]  
KIM HC, 1990, HEMATOLOGY, P1611