Determination of aluminum in serum by electrothermal atomic absorption spectrometry with prior sample pretreatment by microwave digestion and solid-phase extraction

被引:3
作者
Chen, SC
Lan, CR
Yang, MH
机构
[1] NATL TSING HUA UNIV,DEPT NUCL SCI,HSINCHU 30043,TAIWAN
[2] TAIWAN POWER CO,POWER RES INST,CHEM LAB,TAIPEI 23802,TAIWAN
关键词
aluminum; serum; microwave digestion; solid-phase extraction; electrothermal atomic absorption spectrometry;
D O I
10.2116/analsci.13.415
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microwave-assisted digestion system enabling simultaneous treatment of thirty-six samples with oxidizing acidic media in double-closed vessels was devised. Aluminum was subsequently separated from the digested solution through solid phase extraction by prior reacting with 8-quinolinol and adsorbing onto the simple XAD-4 resin column. In the separated fraction, Al, being in a state free from matrix interferences, can be directly determined with electrothermal atomic absorption spectrometry (ETAAS) simply by an external calibration standard. With meticulous control of analytical blank introduced in the sample pretreatment steps, a good performance of analytical accuracy and limit of detection can be achieved. The proposed method, featuring freedom from potential interference in ETAAS and relatively fast sample throughput, can conveniently serve as a reference and/or an alternative method for the direct ETAAS method commonly used for routine clinical purposes.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 28 条
[1]   DETERMINATION OF ALUMINUM BY INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS IN BIOLOGICAL SAMPLES WITH SPECIAL REFERENCE TO NBS-SRM-1577 BOVINE LIVER [J].
ALFASSI, ZB ;
RIETZ, B .
ANALYST, 1994, 119 (11) :2407-2410
[2]   DETERMINATION OF ALUMINUM IN BLOOD, URINE, AND WATER BY INDUCTIVELY COUPLED PLASMA EMISSION SPECTROMETRY [J].
ALLAIN, P ;
MAURAS, Y .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2089-2091
[3]  
BERTHOLF RL, 1983, CLIN CHEM, V29, P1087
[4]  
BROWN S, 1984, CLIN CHEM, V30, P1216
[5]  
CARSON BL, 1986, TOXICOLOGY BIOL MONI, P16
[6]  
CEDERGREN A, 1987, PURE APPL CHEM, V59, P21
[7]   COMPARISON BETWEEN NEUTRON-ACTIVATION ANALYSIS AND GRAPHITE FURNACE ATOMIC-ABSORPTION SPECTROMETRY FOR TRACE ALUMINUM DETERMINATION IN BIOLOGICAL-MATERIALS [J].
GARMESTANI, K ;
BLOTCKY, AJ ;
RACK, EP .
ANALYTICAL CHEMISTRY, 1978, 50 (01) :144-147
[8]  
GITELMAN HJ, 1989, CLIN CHEM, V35, P1517
[9]  
HENNION MC, 1994, ENVIRON SCI TECHNOL, V28, pA576, DOI 10.1021/es00062a717
[10]   DETERMINATION OF SILICON AND ALUMINUM IN BIOLOGICAL MATRICES BY INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY [J].
LICHTE, FE ;
HOPPER, S ;
OSBORN, TW .
ANALYTICAL CHEMISTRY, 1980, 52 (01) :120-124