Hepatic metastases: Diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR imaging

被引:252
作者
Nasu, K
Kuroki, Y
Nawano, S
Kuroki, S
Tsukamoto, T
Yamamoto, S
Motoori, K
Ueda, T
机构
[1] Natl Canc Ctr Hosp E, Dept Diagnost Radiol, Kashiwa, Chiba 2778577, Japan
[2] Natl Canc Ctr, Dept Diagnost Radiol, Tokyo, Japan
[3] Kofu Kyoritu Hosp, Dept Radiol, Yamanashi, Japan
[4] Chiba Univ, Sch Med, Dept Radiol, Chiba 280, Japan
关键词
D O I
10.1148/radiol.2383041384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively compare accuracy of diffusion-weighted (DW) single-shot echo-planar imaging with sensitivity encoding (SENSE) with that of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging in the evaluation of hepatic metastases due to the extrahepatic malignancies. Materials and Methods: Patients provided informed consent; ethics committee approval was not required. The data of 24 patients (16 men, eight women; age range, 41-68 years; mean age. 61.9 years) with 40 resected hepatic metastases were retrospectively reviewed. Before SPIO administration, DW SENSE imaging and T2-weighted fast spin-echo (SE) and T1-weighted dual-echo fast field-echo (FFE) MR imaging were performed. After SPIO administration, T2*-weighted fast SE, T1-weighted dual-echo, and T2*-weighted FFE MR examinations were performed. Images were divided into two sets: The SPIO-enhanced MR image set consisted of pre- and postcontrast T2-weighted fast SE and dual-echo T1-weighted images and postcontrast T2*-weighted FFE images. The DW SENSE image set included DW SENSE images and precontrast T2-weighted fast. SE and dual-echo T1-weighted FFE images. Three radiologists individually interpreted these images and sorted the confidence levels for presence of hepatic metastasis in each section into five grades. Area under the receiver operating characteristic (ROC) curve (A(z)) was calculated for each image set. Results: Hepatic metastases showed higher signal intensity on DW SENSE images than on T2-weighted fast SE images. Conversely, signals from vessels and cysts were suppressed with DW SENSE imaging. ROC analysis showed higher A(z) values when the DW SENSE image set was interpreted (0.90) than when the SPIO-enhanced MR image set was interpreted (0.81). The sensitivity and specificity, respectively, of total cases were 0.66 and 0.90, for the SPIO-enhanced MR image set and 0.82 and 0.94 for the DW SENSE image set. During SPIO-enhanced MR image imterpretation, lesions 1 cm in diameter or smaller showed significantly lower sensitivity than lesions larger than 1 cm in diameter. During both interpretation sessions, left lobe lesions showed significantly lower sensitivity than right lobe lesions. Conclusion: Combined reading of DW SENSE images and T2-weighted fast SE and dual-echo T1-weighted FFE MR images showed higher accuracy in the detection of hepatic metastases than did reading of SPIO-enhanced MR images.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 30 条
  • [1] RECENT ADVANCES IN MR IMAGING SPECTROSCOPY OF CEREBRAL-ISCHEMIA
    BAKER, LL
    KUCHARCZYK, J
    SEVICK, RJ
    MINTOROVITCH, J
    MOSELEY, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (06) : 1133 - 1143
  • [2] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [3] Acute cerebral infarction: Quantification of spin-density and T2 shine-through phenomena on diffusion-weighted MR images
    Burdette, JH
    Elster, AD
    Ricci, PE
    [J]. RADIOLOGY, 1999, 212 (02) : 333 - 339
  • [4] Fong YM, 1999, SEMIN ONCOL, V26, P514
  • [5] Evaluating pediatric brain tumor cellularity with diffusion-tensor imaging
    Gauvain, KM
    McKinstry, RC
    Mukherjee, P
    Perry, A
    Neil, JJ
    Kaufman, BA
    Hayashi, RJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 449 - 454
  • [6] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [7] Diffusion-weighted MR imaging with a single-shot echoplanar sequence: Detection and characterization of focal hepatic lesions
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 397 - 402
  • [8] Characterization of focal hepatic lesions with ferumoxides-enhanced MR imaging: Utility of T1-weighted spoiled gradient recalled echo images using different echo times
    Kim, JH
    Kim, MJ
    Suh, SH
    Chung, JJ
    Yoo, HS
    Lee, JT
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) : 573 - 583
  • [9] Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: A comparative study using seven pulse sequences
    Kim, SH
    Choi, D
    Lim, JH
    Lee, WJ
    Jang, HJ
    Lim, HK
    Lee, SJ
    Cho, JM
    Kim, SK
    Kim, GC
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2002, 3 (02) : 87 - 97
  • [10] Diffusion-weighted single-shot echoplanar MR imaging for liver disease
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Tsuda, K
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) : 393 - 398