Comparative study of four fluorescent probes for evaluation of natural killer cell cytotoxicity assays

被引:48
作者
Cholujova, Dana [2 ]
Jakubikova, Jana [1 ]
Kubes, Miroslav [3 ]
Arendacka, Barbora [4 ]
Sapak, Michal [5 ]
Ihnatko, Robert [3 ]
Sedlak, Jan [1 ]
机构
[1] Slovak Acad Sci, Canc Res Inst, Lab Tumor Immunol, Bratislava, Slovakia
[2] Slovak Acad Sci, Canc Res Inst, Mol Oncol Lab, Bratislava, Slovakia
[3] Slovak Acad Sci, Inst Virol, Bratislava, Slovakia
[4] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[5] Comenius Univ, Fac Med, Inst Immunol, Bratislava, Slovakia
关键词
Calcein-AM; CFSE; Cr release; Cytotoxicity; Mitotracker Green; Natural killer; Vybrant DiO;
D O I
10.1016/j.imbio.2008.02.006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Cytotoxicity is one of the major defence mechanisms against both virus-infected and tumor cells. Radioactive (51)chromium (Cr-51) release assay is a "gold standard" For assessment of natural killer (NK) cytolytic activity in vitro. Several disadvantages of this assay led LIS to design alternative tools based oil flow cytometry analysis. Four different fluorescent dyes, calcein acetoxymethyl ester (CAM), carboxyfluorescein succinimidyl ester (CFSE), Vybrant DiO (DiO) and MitoTracker Green (MTG) were tested for labeling of NK target K-562 cells. Target staining stability, Spontaneous release Of fluorochromes and Subsequent accumulation in bystander unstained cells were measured using fluorimetry and flow cytometry. Healthy donor peripheral blood mononuclear cells and affinity column Purified NK Cells Were used Lis effectors coincubated with target K-562 cells at different E:T ratios for 3 h a rid respectively. Fluorescent probe 7-amino-actinomycin D was used for live and dead cell discrimination. Bland-Altman statistical method was applied to measure true agreement for all CAM-Cr-51, CFSE-Cr-51, DiO-Cr-51 and MTG-Cr-51 pairs analyzed. Based on the data, none of the four proposed methods call be stated equivalent to the standard Cr-51 release assay. Considering linear relationships between data obtained with four fluorochromes and 5 1 Cl, release assay as well as linear regression analysis with R-2 = 0.9393 value for CAM-Cr-51 pair, we Found the CAM assay to be the most closely related to the Cr-51 assay. (C) 2008 Elsevier GmbH. All rights reserved.
引用
收藏
页码:629 / 640
页数:12
相关论文
共 49 条
[1]   DYNAMIC BEHAVIOR OF FLUORESCENT PROBES IN LIPID BILAYER MODEL MEMBRANES [J].
BADLEY, RA ;
SCHNEIDER, H ;
MARTIN, WG .
BIOCHEMISTRY, 1973, 12 (02) :268-275
[2]  
BRUNNER KT, 1968, IMMUNOLOGY, V14, P181
[3]   CALCULATION OF LYTIC UNITS FOR THE EXPRESSION OF CELL-MEDIATED CYTOTOXICITY [J].
BRYANT, J ;
DAY, R ;
WHITESIDE, TL ;
HERBERMAN, RB .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 146 (01) :91-103
[4]   Three-color flow cytometric assay for the study of the mechanisms of cell-mediated cytotoxicity [J].
Derby, E ;
Reddy, V ;
Kopp, W ;
Nelson, E ;
Baseler, M ;
Sayers, T ;
Malyguine, A .
IMMUNOLOGY LETTERS, 2001, 78 (01) :35-39
[5]   Relationship between cytotoxic drug response patterns and activity of drug efflux transporters mediating multidrug resistance [J].
Dhar, S ;
Nygren, P ;
Liminga, G ;
Sundström, C ;
de la Torre, M ;
Nilsson, K ;
Larsson, R .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1998, 346 (2-3) :315-322
[6]   The flow cytometric PKH-26 assay for the determination of T-cell mediated cytotoxic activity [J].
Fischer, K ;
Mackensen, A .
METHODS, 2003, 31 (02) :135-142
[7]   A novel method for measuring CTL and NK cell-mediated cytotoxicity using annexin V and two-color flow cytometry [J].
Goldberg, JE ;
Sherwood, SW ;
Clayberger, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 224 (1-2) :1-9
[8]   A flow-cytometry based cytotoxicity assay using stained effector cells in combination with native target cells [J].
Höppner, M ;
Luhm, J ;
Schlenke, P ;
Koritke, P ;
Frohn, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 267 (02) :157-163
[9]   A NEW APPROACH FOR MEASUREMENT OF CYTOTOXICITY USING COLORIMETRIC ASSAY [J].
HUSSAIN, RF ;
NOURI, AME ;
OLIVER, RTD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 160 (01) :89-96
[10]   CELL-MEDIATED LYMPHOLYSIS - A MODIFIED TECHNIQUE USING INDIUM-111-OXINE-LABELED TARGETS [J].
JAKUBEK, P ;
THORSBY, E ;
HIRSCHBERG, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 60 (03) :379-390