Accuracy and Reliability of Continuous Glucose Monitoring Systems: A Head-to-Head Comparison

被引:54
作者
Luijf, Yoeri M. [1 ]
Mader, Julia K. [2 ]
Doll, Werner [2 ]
Pieber, Thomas [2 ]
Farret, Anne [3 ,4 ,5 ]
Place, Jerome [3 ,4 ,5 ]
Renard, Eric [3 ,4 ,5 ]
Bruttomesso, Daniela [6 ]
Filippi, Alessio [6 ]
Avogaro, Angelo [6 ]
Arnolds, Sabine [7 ]
Benesch, Carsten [7 ]
Heinemann, Lutz [7 ]
DeVries, J. Hans [1 ]
机构
[1] Acad Med Ctr, NL-1100 DD Amsterdam, Netherlands
[2] Med Univ Graz, Dept Internal Med, Graz, Austria
[3] Montpellier Univ Hosp, Dept Endocrinol, Montpellier, France
[4] INSERM 1001, Clin Invest Ctr, Montpellier, France
[5] CNRS, INSERM, UMR 5203, U661, Montpellier, France
[6] Univ Padua, Dept Clin & Expt Med, Padua, Italy
[7] Profil Inst Stoffwechselforsch GmbH, Neuss, Germany
关键词
BLOOD-GLUCOSE;
D O I
10.1089/dia.2013.0049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. Research Design and Methods: We studied the Animas (R) (West Chester, PA) Vibe (TM) with Dexcom (R) (San Diego, CA) G4 (TM) version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle (R) Navigator I (NAV), and the Medtronic (Northridge, CA) Paradigm (R) with Enlite (TM) sensor (ENL) in 20 patients with type 1 diabetes mellitus. All systems were investigated both in a clinical research center (CRC) and at home. In the CRC, patients received a meal with a delayed and increased insulin dose to induce a postprandial glucose peak and nadir. Hereafter, randomization determined which two of the three systems would be worn at home until the end of functioning, attempting use beyond manufacturer-specified lifetime. Patients performed at least five reference finger sticks per day. An analysis of variance was performed on all data points 15min apart. Results: Overall average mean absolute relative difference (MARD) (SD) measured at the CRC was 16.5% (14.3%) for NAV and 16.4% (15.6%) for ENL, outperforming G4A at 20.5% (18.2%) (P < 0.001). Overall MARD when assessed at home was 14.5% (16.7%) for NAV and 16.5 (18.8%) for G4A, outperforming ENL at 18.9% (23.6%) (P = 0.006). Median time until end of functioning was similar: 10.0 (1.0) days for G4A, 8.0 (3.5) days for NAV, and 8.0 (1.5) days for ENL (P = 0.119). Conclusions: In the CRC, G4A was less accurate than NAV and ENL sensors, which seemed comparable. However, at home, ENL was less accurate than NAV and G4A. Moreover, CGM systems often show sufficient accuracy to be used beyond manufacturer-specified lifetime.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 10 条
[1]   Frequency characterization of blood glucose dynamics [J].
Gough, DA ;
Kreutz-Delgado, K ;
Bremer, TM .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (01) :91-97
[2]  
Heinemann Lutz, 2012, J Diabetes Sci Technol, V6, P1498
[3]   Sense and nonsense in sensors [J].
Hermanides, J. ;
DeVries, J. H. .
DIABETOLOGIA, 2010, 53 (04) :593-596
[4]   Continuous glucose monitoring systems for type 1 diabetes mellitus [J].
Langendam, Miranda W. ;
Luijf, Yoeri M. ;
Hooft, Lotty ;
DeVries, J. Hans ;
Mudde, Aart H. ;
Scholten, Rob J. P. M. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01)
[5]  
Luijf Yoeri M, 2012, J Diabetes Sci Technol, V6, P1103
[6]   The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes [J].
Mastrototaro, John ;
Shin, John ;
Marcus, Alan ;
Sulur, Giri .
DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) :385-390
[7]   Comparison of the Clinical Information Provided by the FreeStyle Navigator Continuous Interstitial Glucose Monitor Versus Traditional Blood Glucose Readings [J].
McGarraugh, Geoffrey V. ;
Clarke, William L. ;
Kovatchev, Boris P. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (05) :365-371
[8]   Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients [J].
Wentholt, IM ;
Vollebregt, MA ;
Hart, AA ;
Hoekstra, JB ;
DeVries, JH .
DIABETES CARE, 2005, 28 (12) :2871-2876
[9]   Relationship between interstitial and blood glucose in type 1 diabetes patients: Delay and the push-pull phenomenon revisited [J].
Wentholt, Iris M. E. ;
Hart, Augustus A. M. ;
Hoekstra, Joost B. L. ;
Devries, J. Hans .
DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (02) :169-175
[10]  
Zisser Howard C, 2009, J Diabetes Sci Technol, V3, P1146