Automatic detection of atrial fibrillation using the coefficient of variation and density histograms of RR and ΔRR intervals

被引:224
作者
Tateno, K [1 ]
Glass, L [1 ]
机构
[1] McGill Univ, Dept Physiol, Montreal, PQ, Canada
关键词
atrial fibrillation; RR interval; coefficient of variation; Kolmogorov-Smirnov test;
D O I
10.1007/BF02345439
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The paper describes a method for the automatic detection of atrial fibrillation, an abnormal heart rhythm, based on the sequence of intervals between heartbeats. The RR interval is the interbeat interval, and Delta RR is the difference between two successive RR intervals. Standard density histograms of the RR and Delta RR intervals were prepared as templates for atrial fibrillation detection. As the coefficients of variation of the RR and Delta RR intervals were approximately constant during atrial fibrillation, the coefficients of variation in the test data could be compared with the standard coefficients of variation (CV test). Further, the similarities between the density histograms of the test data and the standard density histograms were estimated using the Kolmogorov-Smirnov test. The CV test based on the RR intervals showed a sensitivity of 86.6% and a specificity of 84.3%. The CV test based on the Delta RR intervals showed that the sensitivity and the specificity are both approximately 84%. The Kolmogorov-Smirnov test based on the RR intervals did not improve on the result of the CV test. In contrast, the Kolmogorov-Smirnov test based on the Delta RR intervals showed a sensitivity of 94.4% and a specificity of 97.2%.
引用
收藏
页码:664 / 671
页数:8
相关论文
共 11 条
[1]  
Andresen D, 1998, J CARDIOVASC ELECTR, V9, pS26
[2]   ANALYSIS OF R-R INTERVALS IN PATIENTS WITH ATRIAL FIBRILLATION AT REST AND DURING EXERCISE [J].
BOOTSMA, BK ;
HOELEN, AJ ;
STRACKEE, J ;
MEIJLER, FL .
CIRCULATION, 1970, 41 (05) :783-&
[3]  
Hulley SB, 1988, DESIGNING CLIN RES
[4]   AV nodal function during atrial fibrillation: The role of electrotonic modulation of propagation [J].
Meijler, FL ;
Jalife, J ;
Beaumont, J ;
Vaidya, D .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (09) :843-861
[5]  
Meijler Frits L., 1997, P109
[6]  
Moody G. B., 1983, Computers in Cardiology 10th Annual Meeting (IEEE Cat. No. 83CH1927-3), P227
[7]   IDENTIFICATION OF ATRIAL-FIBRILLATION EPISODES IN AMBULATORY ELECTROCARDIOGRAPHIC RECORDINGS - VALIDATION OF A METHOD FOR OBTAINING LABELED R-R INTERVAL FILES [J].
MURGATROYD, FD ;
XIE, BY ;
COPIE, X ;
BLANKOFF, I ;
CAMM, AJ ;
MALIK, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06) :1315-1320
[8]  
Pinciroli F., 1986, Automedica, V6, P295
[9]  
SLOCUM J, 1987, COMPUT CARDIOL, V13, P253
[10]   A method for detection of atrial fibrillation using RR intervals [J].
Tateno, K ;
Glass, L .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :391-394