Development of a ten-station, multi-axis hip joint simulator

被引:26
作者
Goldsmith, AAJ [1 ]
Dowson, D [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
hip simulator; total hip replacement; wear;
D O I
10.1243/0954411991535149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Joint simulators are now used extensively to evaluate the performance of materials and designs of total replacement hip and knee joints. In this Technical Note a new ten-station hip joint simulator with biaxial rotational articulation synchronized to a physiological loading cycle is described. The current simulator manufactured by ProSim Limited (Manchester, UK) is a development of a first generation machine designed and built in-house at DePuy International Limited (Leeds, UK). The use of this new form of ten-station hip simulator to evaluate the performance of 22 mm zirconia femoral heads and ultra-high molecular weight polyethylene acetabular cups over some 7 million loading cycles is described elsewhere [1].
引用
收藏
页码:311 / 316
页数:6
相关论文
共 9 条
[1]  
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[2]   Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear [J].
Clarke, IC ;
Good, V ;
Anissian, L ;
Gustafson, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :25-36
[3]  
Dowson D, 1988, Eng Med, V17, P111, DOI 10.1243/EMED_JOUR_1988_017_031_02
[4]   A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints [J].
Goldsmith, AAJ ;
Dowson, D .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) :77-90
[5]   THE WEAR BEHAVIOR OF ION-IMPLANTED TI-6AL-4V AGAINST UHMW POLYETHYLENE [J].
MCKELLOP, HA ;
ROSTLUND, TV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (11) :1413-1425
[6]   Kinematics of the MATCO(TM) hip simulator and issues related to wear testing of metal-metal implants [J].
Medley, JB ;
Krygier, JJ ;
Bobyn, JD ;
Chan, FW ;
Lippincott, A ;
Tanzer, M .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :89-99
[7]  
Mejia Lito C., 1994, Bio-Medical Materials and Engineering, V4, P259
[8]  
Saikko V O, 1996, Proc Inst Mech Eng H, V210, P175, DOI 10.1243/PIME_PROC_1996_210_410_02
[9]  
SMITH SL, 1997, BRIT ORTH RES SOC M