Quantitative analysis of the functionality and efficiency of three surgical dissection techniques: A time-motion analysis

被引:42
作者
Den Boer, KT
Straatsburg, IH
Schellinger, AV
De Wit, LT
Dankelman, J
Gouma, DJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Surg, NL-1100 DE Amsterdam, Netherlands
[2] Delft Univ Technol, Fac Design Engn & Prod, Delft, Netherlands
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A | 1999年 / 9卷 / 05期
关键词
D O I
10.1089/lap.1999.9.389
中图分类号
R61 [外科手术学];
学科分类号
摘要
The increasing technological complexity of surgery demands objective evaluation of surgical techniques. In particular, alternatives for laparoscopic ligation, such as monopolar coagulation and the relatively new bipolar scissors combining dissection with coagulation, should be analyzed and compared. This study tests the efficacy of quantitative time-motion analysis in evaluating and comparing the functionality and efficiency of dissection and ligation techniques in a clinical setting. Standard dissection with ligation of vessels, bipolar scissors, and monopolar coagulation were consecutively applied to dissect 4 of the small bowel mesentery of pigs, in random order. All actions performed were recorded and analyzed, using a standard action list. The efficiency of each technique was expressed in mean dissection time and number of actions, and the safety in occurrence of complications and severity of microscopic damage. Time-motion analysis evaluated the efficiency objectively and reproducibly (ICC 0.98). Bipolar scissors were significantly more efficient (time 7 +/- 2 min? actions 129 +/- 33) than the standard technique (28 +/- 6, 771 +/- 185) and monopolar coagulation (14 +/- 5, 368 +/- 32) (p < 0.01). Furthermore, bipolar coagulation needed significantly less recoagulation of an oozing vessel (0.5% of the total dissected vessels) than did monopolar coagulation (10.4 %), and the damaged zone was significantly smaller (p < 0.05). Significantly less time was spent waiting or exchanging instruments with bipolar scissors than with the standard technique (p < 0.05). This time-motion analysis objectively compared the efficiency and functionality of three surgical dissection techniques during clinical use. Bipolar scissors were more efficient than were both other techniques, and they coagulated vessels more safely than did monopolar coagulation.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 17 条
[1]  
BAGGISH MS, 1995, FERTIL STERIL, V63, P422
[2]   Surgical technology and the ergonomics of laparoscopic instruments [J].
Berguer, R .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (05) :458-462
[3]  
Berguer Ramon, 1997, Reviews on Environmental Health, V12, P99
[4]  
Claus G P, 1995, Endosc Surg Allied Technol, V3, P210
[5]   COMPARISON OF DIRECT VISION AND ELECTRONIC 2-DIMENSIONAL AND 3-DIMENSIONAL DISPLAY SYSTEMS ON SURGICAL TASK EFFICIENCY IN ENDOSCOPIC SURGERY [J].
CROSTHWAITE, G ;
CHUNG, T ;
DUNKLEY, P ;
SHIMI, S ;
CUSCHIERI, A .
BRITISH JOURNAL OF SURGERY, 1995, 82 (06) :849-851
[6]   WHITHER MINIMAL ACCESS SURGERY - TRIBULATIONS AND EXPECTATIONS [J].
CUSCHIERI, A .
AMERICAN JOURNAL OF SURGERY, 1995, 169 (01) :9-19
[7]   The impact of technologies on minimally invasive therapy [J].
Cuschieri, A ;
Melzer, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (02) :91-92
[8]   Peroperative time-motion analysis of diagnostic laparoscopy with laparoscopic ultrasonography [J].
den Boer, KT ;
de Wit, LT ;
Dankelman, J ;
Gouma, DJ .
BRITISH JOURNAL OF SURGERY, 1999, 86 (07) :951-955
[9]  
EDELMAN DS, 1995, SURG LAPAROSC ENDOSC, V5, P459
[10]   Prehensile atraumatic grasper with intuitive ergonomics [J].
Frank, TG ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (10) :1036-1039