Performance of poly(vinyl alcohol) gel columns on the ion chromatographic determination of perchlorate in fertilizers

被引:5
作者
De Borba, BM
Urbansky, ET [1 ]
机构
[1] US EPA, Off Res & Dev, Natl Risk Management Res Lab, Water Supply & Water Resources Div, Cincinnati, OH 45268 USA
[2] Metrohm Peak Inc, Houston, TX 77034 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2002年 / 4卷 / 01期
关键词
D O I
10.1039/b109120b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in possible sources of perchlorate (ClO4-) that could lead to environmental release has been heightened since the Environmental Protection Agency placed this anion on its. Contaminant Candidate List for drinking water. Although recent investigations have suggested that fertilizers are minor contributors to environmental perchlorate contamination overall, there is still interest in screening commercial products for possible contamination and quantitating perchlorate when it is found. Ion chromatography (IC) has been used for this application owing to its speed, low detection limits, widespread availability, and moderate ruggedness relative to other techniques. However, fertilizer matrixes complicate the IC analysis relative to potable water matrixes. In this study, the performance of poly(vinyl alcohol) gel resin IC columns (100 mm and 150 mm) was evaluated for fertilizer matrixes using method EPA/600/R-01/026. The NaOH eluent included an organic salt, sodium 4-cyanophenoxide. Detection was by suppressed conductivity. A set of 55 different field samples representing 48 products and previously used by the EPA to assess occurrence of perchlorate in fertilizers (EPA/600/R-01/049) was reanalyzed on the 150 mm column. The 100 mm column was used to further investigate the positive hits. Both columns gave satisfactory performance in fertilizer matrixes, with spike recoveries (+/-15%), assured reporting levels (0.5-225 mug g(-1) except for one at 1000 mug g(-1)), accuracy (relative error < 30% always and most < 15%), and precision [injection-to-injection reproducibility < 3% relative standard deviation (RSD)] comparable to those reported in other studies. Performance did not vary substantially between column lengths. Lastly, the results of this investigation provided further evidence in support of the conclusions that had been reached previously by the EPA on the occurrence of perchlorate in fertilizers.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 27 条
[1]  
CLARK JJJ, 2000, PERCHLORATE ENV, pCH3
[2]  
COLLETTE TW, 2000, AM CHEM SOC 220 NAT
[3]  
De Barba BM, 2001, AM LAB, V33, P22
[4]  
ELDRIDGE JE, 1999, AFRLHEWPTR20000037
[5]  
ERICKSEN GE, 1983, AM SCI, V71, P366
[6]  
GU B, 2000, AM CHEM SOC 220 NAT
[7]  
Gullick RQ, 2001, J AM WATER WORKS ASS, V93, P66
[8]  
HAUTMAN DP, 1999, EPA814B99003
[9]  
Okamoto HS, 1999, J AM WATER WORKS ASS, V91, P73
[10]   Study finding perchlorate in fertilizer rattles industry [J].
Renner, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (19) :394A-395A