Comparative biomechanics of hybrid external fixation

被引:44
作者
Pugh, KJ
Wolinsky, PR
Pienkowski, D
Banit, D
Dawson, JM
机构
[1] Univ Kentucky, Dept Surg, Div Orthopaed, Lexington, KY 40536 USA
[2] Vanderbilt Univ, Dept Orthopaed & Rehabil, Nashville, TN USA
关键词
external fixation; hybrid fixator; biomechanics; Pilon fracture; tibial plateau fracture;
D O I
10.1097/00005131-199908000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the elastic stiffness, in several loading modes, of commercially available hybrid external fixation systems. Design: Laboratory investigation using a polyvinylchloride pipe periarticular tibia fracture model. Setting: Simulated periarticular fractures were created in an in vitro tibia fracture model. instrumented specimens and intact controls were elastically tested in a biomaterials testing system. Intervention: Groups of simulated periarticular tibia fractures were stabilized with one of six different hybrid external fixator designs. Main Outcome Measurements: Elastic stiffness of each specimen was measured in compression, torsion, flexion bending, extension bending, and varus/valgus bending. Results: Fixators with multiple levels of fixation in the peri articular fragment, regardless of design, were stiffer than those with one level. Specifically, the EBI Ring Connector fixator was stiffer than all others in all modes of testing. The Ace, Synthes, Smith & Nephew Richards, and Howmedica fixators were mechanically similar. The Zimmer Torus fixator was the least stiff fixator tested. Conclusions: Fixators with multiple levels of fixation in the periarticular fragment, regardless of design, were stiffer than those with one level. The: choice of which hybrid external fixator to use should be made based not only on stiffness but also on ease of clinical application, patient comfort, customer support from the manufacturer, and cost. Clinical investigation of the efficacy of each of these devices is warranted.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 24 条
[1]
BEHRENS F, 1989, CLIN ORTHOP RELAT R, P48
[2]
UNILATERAL EXTERNAL FIXATION FOR SEVERE PILON FRACTURES [J].
BONAR, SK ;
MARSH, JL .
FOOT & ANKLE, 1993, 14 (02) :57-64
[3]
BONAR SK, 1994, J AM ACAD ORTHOP SUR, V2, P297
[4]
BONE L, 1993, CLIN ORTHOP RELAT R, P101
[5]
CALHOUN JH, 1992, CLIN ORTHOP RELAT R, P15
[6]
FLEMING B, 1989, CLIN ORTHOP RELAT R, P95
[7]
KARAS EH, 1994, ORTHOP CLIN N AM, V25, P651
[8]
Fracture site motion with ilizarov and "hybrid" external fixation [J].
Khalily, C ;
Voor, MJ ;
Seligson, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (01) :21-26
[9]
KUMMER FJ, 1992, CLIN ORTHOP RELAT R, P11
[10]
Biomechanical comparison of hybrid external fixators [J].
Lundy, DW ;
Albert, MJ ;
Hutton, WC .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (07) :496-503