Correction of through-plane deformation artifacts in stimulated echo acquisition mode cardiac imaging

被引:15
作者
Fahmy, AS
Pan, L
Stuber, M
Osman, NF
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
关键词
stimulated echo mode; STEAM; cardiac imaging; black-blood; artifact; deformation;
D O I
10.1002/mrm.20781
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.
引用
收藏
页码:404 / 412
页数:9
相关论文
共 17 条
[1]   Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart [J].
Aletras, AH ;
Wen, H .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :523-534
[2]   DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI [J].
Aletras, AH ;
Ding, SJ ;
Balaban, RS ;
Wen, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :247-252
[3]   Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes [J].
Epstein, FH ;
Gilson, WD .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :774-781
[4]   LIMITATIONS OF STIMULATED ECHO ACQUISITION MODE (STEAM) TECHNIQUES IN CARDIAC APPLICATIONS [J].
FISCHER, SE ;
STUBER, M ;
SCHEIDEGGER, MB ;
BOESIGER, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :80-91
[5]   STIMULATED ECHO IMAGING [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :81-93
[6]   HIGH-SPEED STEAM MRI OF THE HUMAN HEART [J].
FRAHM, J ;
HANICKE, W ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) :133-142
[7]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[8]   MULTIPLE CHEMICAL-SHIFT-SELECTIVE NMR IMAGING USING STIMULATED ECHOES [J].
HAASE, A ;
FRAHM, J .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :94-102
[9]   MR IMAGING USING STIMULATED ECHOES (STEAM) [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
BOMSDORF, H ;
KUNZ, D ;
TISCHLER, R .
RADIOLOGY, 1986, 160 (03) :787-790
[10]   Increasing the signal-to-noise ratio in DENSE MRI by combining displacement-encoded echoes [J].
Kim, D ;
Epstein, FH ;
Gilson, WD ;
Axel, L .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :188-192