Effect of different sample types and stability after blood collection of N-terminal Pro-B-type natriuretic peptide as measured with Roche elecsys system

被引:18
作者
van der Merwe, DE [1 ]
Henley, R
Lane, G
Field, R
Frenneaux, M
Dunstan, F
McDowell, I
机构
[1] Univ Wales Hosp, Dept Med Biochem & Immunol, Cardiff CF14 4XW, S Glam, Wales
[2] Univ Wales Coll Cardiff, Coll Med, Cardiff CF14 4XW, S Glam, Wales
[3] Univ Wales Hosp, Dept Cardiol, Cardiff CF14 4XW, S Glam, Wales
[4] Univ Wales Hosp, Dept Med Stat, Cardiff CF14 4XW, S Glam, Wales
关键词
D O I
10.1373/clinchem.2003.025064
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:779 / 780
页数:2
相关论文
共 7 条
[1]   Stability of NT-proBNP in serum specimens collected in Becton Dickinson vacutainer (SST) tubes [J].
Dasgupta, A ;
Chow, L ;
Tso, G ;
Nazareno, L .
CLINICAL CHEMISTRY, 2003, 49 (06) :958-960
[2]   Assessment of the stability of N-terminal pro-brain natriuretic peptide in vitro:: implications for assessment of left ventricular dysfunction [J].
Downie, PF ;
Talwar, S ;
Squire, IB ;
Davies, JE ;
Barnett, DB ;
Ng, LL .
CLINICAL SCIENCE, 1999, 97 (03) :255-258
[3]   Stability of brain natriuretic peptide (BNP) in human whole blood and plasma [J].
Gobinet-Georges, A ;
Valli, N ;
Filliatre, H ;
Dubernet, MF ;
Dedeystere, O ;
Bordenave, L .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (06) :519-523
[4]   Disparity between studies of the stability of BNP in blood: comparison of endogenous and exogenous peptide [J].
Murdoch, DR ;
Byrne, J ;
Farmer, R ;
Morton, JJ .
HEART, 1999, 81 (02) :212-213
[5]  
*ROCH DIAGN GMBH, 2002, EL NT PROBNP
[6]  
Sokoll LJ, 2002, CLIN CHEM, V48, pA91
[7]   Biological variation for N-terminal pro- and B-type natriuretic peptides and implications for therapeutic monitoring of patients with congestive heart failure [J].
Wu, AHB ;
Smith, A ;
Wieczorek, S ;
Mather, JF ;
Duncan, B ;
White, CM ;
McGill, C ;
Katten, D ;
Heller, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (05) :628-631