Simulation-based investigation of partially parallel imaging with a linear array at high accelerations

被引:18
作者
Bankson, JA [1 ]
Wright, SM [1 ]
机构
[1] Texas A&M Univ, Dept Elect Engn, College Stn, TX 77843 USA
关键词
SMASH; SENSE; phased arrays; parallel imaging; array design;
D O I
10.1002/mrm.10113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partially parallel imaging strategies such as SMASH, SENSE, and PILS rely on the sensitivity distribution of phased array RF coils to reduce MRI imaging time. Using an N-element phased array, these techniques allow maximum accelerations, L, such that L less than or equal to N, with acceleration defined as the factor by which scan time is reduced in comparison to traditional, fully gradient encoded acquisitions. As N increases in modern MRI facilities or using special hardware extensions, its role as the primary limitation in partially parallel imaging will be reduced and other limiting factors will become dominant. Two such factors include available SNR and the variation of sensitivity distributions with imaging depth. Simulations have been conducted to evaluate the impact of slice depth and noise on partially parallel reconstructions for the case of a square linear array of overlapped elements that are parallel to the imaging plane. Results indicate that even when sensitivity distributions are exactly known, the linear surface array can only provide high accelerations over a limited imaging depth due to changing suitability of the sensitivity distributions for partially parallel reconstruction. This work emphasizes the importance of simulations for target-based partially parallel array design. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:777 / 786
页数:10
相关论文
共 23 条
[1]  
Bankson JA, 2000, MAGN RESON MATER PHY, V10, P93
[2]   IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
CARLSON, JW ;
MINEMURA, T .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :681-688
[3]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[4]  
2-5
[5]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[6]  
Horn R. A., 1986, Matrix analysis
[7]   FAST MRI DATA ACQUISITION USING MULTIPLE DETECTORS [J].
HUTCHINSON, M ;
RAFF, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (01) :87-91
[8]   PARALLEL IMAGE ACQUISITION FROM NONINTERACTING LOCAL COILS [J].
HYDE, JS ;
JESMANOWICZ, A ;
FRONCISZ, W ;
KNEELAND, JB ;
GRIST, TM ;
CAMPAGNA, NF .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (03) :512-517
[9]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
[10]  
KELTON JR, 1989, ALGORITHM RAPID IMAG