Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine

被引:76
作者
Kataoka, H [1 ]
Lord, HL [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 731卷 / 02期
关键词
automated in-tube solid-phase microextraction; mass spectrometry; solid-phase microextraction; ranitidine;
D O I
10.1016/S0378-4347(99)00237-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary column by repeated aspirate/dispense steps. In order to optimize the extraction of ranitidine, several in-tube SPME parameters such as capillary column stationary phase, extraction pH and number and volume of aspirate/dispense steps were investigated. The optimum extraction conditions for ranitidine from aqueous samples were 10 aspirate/dispense steps of 30 mu l of sample in 25 mM Tris-HCl (pH 8.5) with an Omegawax 250 capillary column (60 cmx0.25 mm LD., 0.25 mu m film thickness). The ranitidine extracted on the capillary column was easily desorbed with methanol, and then transported to the Supelcosil LC-CN column with the mobile phase methanol-2-propanol-5 M ammonium acetate (50:50:1). The ranitidine eluted from the column was determined by ESI-MS in selected ion monitoring mode. In-tube SPME followed by LC-ESI-MS was performed automatically using the HP 1100 autosampler. Each analysis required 16 min, and carryover of ranitidine in this system was below 1%. The calibration curve of ranitidine in the range of 5-1000 ng/ml was linear with a correlation coefficient of 0.9997 (n=24), and a detection limit at a signal-to-noise ratio of three was ca. 1.4 ng/ml. The within-day and between-day variations in ranitidime analysis were 2.5 and 6.2% (n=5), respectively. This method was also applied for the analyses of tablet and urine samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 50 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
BEUREAU N, 1988, J PHARM SCI, V77, P889
[3]   Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of alkylphenol ethoxylate surfactants in water [J].
BoydBoland, AA ;
Pawliszyn, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1521-1529
[4]  
Bradshaw J., 1979, BRIT J PHARMACOL, V66, P464
[5]   RANITIDINE - A REVIEW OF ITS PHARMACOLOGY AND THERAPEUTIC USE IN PEPTIC-ULCER DISEASE AND OTHER ALLIED DISEASES [J].
BROGDEN, RN ;
CARMINE, AA ;
HEEL, RC ;
SPEIGHT, TM ;
AVERY, GS .
DRUGS, 1982, 24 (04) :267-303
[6]  
CALULL CL, 1997, J CHROMATOGR B, V693, P228
[7]   DETERMINATION OF RANITIDINE AND ITS METABOLITES IN HUMAN-URINE BY REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CAREY, PF ;
MARTIN, LE ;
OWEN, PE .
JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01) :161-168
[8]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[9]   Effect of heating the interface on chromatographic performance of solid phase microextraction coupled to high-performance liquid chromatography [J].
Daimon, H ;
Pawliszyn, J .
ANALYTICAL COMMUNICATIONS, 1997, 34 (11) :365-369
[10]   Solid-phase microextraction coupled to gas chromatography: A new method for the analysis of organics in water [J].
Eisert, R ;
Levsen, K .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :143-157