Accommodation functions: Co-dependency and relationship to refractive error

被引:106
作者
Allen, PM
O'Leary, DJ
机构
[1] Anglia Polytech Univ, Dept Optometry & Ophthalm Dispensing, Cambridge CB1 1PT, England
[2] Univ New S Wales, Vis Cooperat Res Ctr, Sydney, NSW 2052, Australia
关键词
accommodation; myopia; refractive error;
D O I
10.1016/j.visres.2005.05.007
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
We assessed the extent to which different accommodative functions are correlated and whether accommodative functions predict the refractive error or the progression of myopia over a 12 month period in 64 young adults (30 myopes and 34 non-myopes). The functions were: amplitude of accommodation; monocular and binocular accommodative facility (6 m and 40 cm); monocular and binocular accommodative response to target distance; AC/A and CA/C ratios, tonic accommodation (dark focus and pinhole), accommodative hysteresis, and nearwork-induced transient myopia. Within groups of related accommodative functions (such as facility measures or open-loop measures) measurements on individuals were generally significantly correlated, however correlations between functions from different groups were generally not significant. Although accommodative amplitude and pinhole (open loop) accommodation were significantly different in myopes than in non-myopes, these functions were unrelated to myopia progression. Facility of accommodation and accommodative lag was independent predictors of myopia progression. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:491 / 505
页数:15
相关论文
共 87 条
[1]
Abbott ML, 1998, OPHTHAL PHYSL OPT, V18, P13, DOI 10.1016/S0275-5408(97)00072-0
[2]
Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes [J].
Allen, PM ;
Radhakrishnan, H ;
O'Leary, DJ .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (03) :245-251
[3]
EPIDEMIOLOGY OF MYOPIA [J].
ANGLE, J ;
WISSMANN, DA .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1980, 111 (02) :220-228
[4]
AMPLITUDE OF ACCOMMODATION FOR DIFFERENT HEAD POSITIONS AND DIFFERENT DIRECTIONS OF EYE GAZE [J].
ATCHISON, DA ;
CLAYDON, CA ;
IRWIN, SE .
OPTOMETRY AND VISION SCIENCE, 1994, 71 (05) :339-345
[5]
CRITICAL SUBJECTIVE MEASUREMENT OF AMPLITUDE OF ACCOMMODATION [J].
ATCHISON, DA ;
CAPPER, EJ ;
MCCABE, KL .
OPTOMETRY AND VISION SCIENCE, 1994, 71 (11) :699-706
[6]
STEADY-STATE ACCOMMODATION AND OCULAR BIOMETRY IN LATE-ONSET MYOPIA [J].
BULLIMORE, MA ;
GILMARTIN, B ;
ROYSTON, JM .
DOCUMENTA OPHTHALMOLOGICA, 1992, 80 (02) :143-155
[7]
BURGE S, 1979, OPTOM WEEKLY, V69, P867
[8]
CHAT WS, 2002, P 9 INT C MY HONG KO, P28
[9]
SINGLE FIGURE INDEXES FOR THE STEADY-STATE ACCOMMODATIVE RESPONSE [J].
CHAUHAN, K ;
CHARMAN, WN .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (03) :217-221
[10]
Chen Jennifer C, 2003, Clin Exp Optom, V86, P323