The effect of adventitious water in hexapole collision cell inductively coupled plasma mass spectrometry

被引:17
作者
Dexter, MA
Appelblad, PK
Ingle, CP
Batey, JH
Reid, HJ
Sharp, BL [1 ]
机构
[1] Univ Loughborough, Dept Chem, Loughborough LE11 3TU, Leics, England
[2] Lulea Univ Technol, Div Inorgan Chem, SE-97187 Lulea, Sweden
[3] Thermo Elemental, Winsford CW7 3BX, Cheshire, England
关键词
D O I
10.1039/b110281h
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
This paper considers several aspects of the role of water in collision cell inductively coupled plasma mass spectrometry. Studies with water and deuterium oxide, employed both as samples and as impurities in the cell gas, were used to investigate the origins of the polyatomic ions. It was found that no new species were formed in the cell as water from the plasma provides the basic reactive components; however, some were greatly enhanced when the cell gas was deliberately wetted. The reactivity of the water/deuterium oxide dominated the cell chemistry when an unreactive gas such as He was used, indicating a need for careful control of water content, but the effects were greatly reduced when a reactive gas such as hydrogen was also employed. It is concluded that water could be a useful reagent molecule, if its partial pressure can be adequately controlled. Seeking complete removal of water from the reagent gas is unnecessary as there is a baseline contribution from the plasma and, in any case, when reactive reagent gases are used its effect is minimal.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 8 条
[1]
[2]
A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[3]
Selective removal of plasma matrix ions in plasma source mass spectrometry [J].
Eiden, GC ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) :317-322
[4]
The use of background ions and a multivariate approach to characterise and optimise the dominant H2-based chemistries in a hexapole collision cell used in ICP-MS [J].
Ingle, CP ;
Appelblad, PK ;
Dexter, MA ;
Reid, EJ ;
Sharp, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :1076-1084
[5]
LIAS SG, 1988, J PHYS CHEM REF DATA, V17, P1
[6]
A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part III. Optimization and analytical performance [J].
Tanner, SD ;
Baranov, VI ;
Vollkopf, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1261-1269
[7]
TANNER SD, 1999, PLASMA SOURCE MASS S, P46
[8]
Turner P., 1997, PLASMA SOURCE MASS S, P28